Chapter 4
Donning and Doffing
68
SAFETY FIRS T
Edition 1 – December 2019
MSA G1 Classic Breathing Apparatus
Distress Signal Unit
Operating the DSU
Follow these steps to operate the MSA Motion Scout.
What
How
Photos
Start
Press the ON/OFF button for approximately one
second.
The DSU emits an alarm sound for a two
second test period.
The status LEDs flash to indicate that the
instrument is switched on.
No
movement
When the operator remains motionless for
approximately 25 seconds, a series of pre-alarm
warnings are emitted for approximately 15
seconds at a reduced sound volume.
Movement will cancel this pre-alarm
immediately.
If the operator does not move during pre-alarm
period, the full alarm will sound after
approximately 15 seconds.
Cancel
alarm
Press the manual ALARM button twice within
one second.