CAUTION
THERE IS NO LIMIT FOR ENGINE
OPERATION USING THE AVGAS-JET
FUEL MIXTURE AS LONG AS 80/87
GRADE AVGAS IS USED AND THE
1:VOLUME RATIO IS OBSERVED. USE
OF 100/130 (100l) GRADE AVGAS-JET
FUEL MIXTURE SHALL BE RESTRICTED
TO 300 HOURS IN ONE OVERHAUL
PERIOD DUE TO THE HIGH LEAD
CONTENT OF THE FUEL.
CAUTION
WHEN MIXING THE FUELS, AVOID HIGH
FLOW RATES. DO NOT EXCEED A
FLOW RATE OF 50 GALLONS PER
MINUTE. ALSO, MAKE SURE THE FUEL
NOZZLE AND FUEL TANK ARE
GROUNDED TO THE AIRCRAFT.
NOTE
Anti-ice additive is needed for the jet fuel-
AVGAS fuel mixture.
NOTE
Prolonged and uninterrupted operation with
only AVGAS mixture will induce lead buildup
on turbine parts. This lead buildup can
cause a gradual power reduction;
consequently, this AVGAS mixture should
be used only for cold weather operation.
During operation with normal Jet A type
turbine fuel, the lead buildup will slowly
dissipate.
When the AVGAS-jet fuel mixture is used in
the engine the lead from the gasoline
accumulates on the turbine and exhaust
collector outlet ducts. The normal
appearance after operation on leaded fuel is
pale yellow powder deposit on the exhaust
system.