SOLOY TURBINE PAC
SECTION 5
POHS CESSNA U/TU 206G
PERFORMANCE
5-12
F.A.A. Approved
October 4, 2005
MAXIMUM RATE OF CLIMB
CONDITIONS:
1. Flaps Up
2. 1810 RPM
3. Maximum Continuous Power, 78 PSI or 738
C TOT
4. Inlet – Normal
WEIGHT
POUNDS
PRESS ALT
FEET
CLIMB
SPEED KIAS
RATE OF CLIMB - FPM
STD
20
C
STD
STD+20
C
3600
0
87
1477
1447
1354
4,000
84
1429
1399
1162
8,000
81
1373
1228
961
12,000
77
1107
959
744
16,000
74
831
709
548
20,000
71
569
477
404
3300
0
86
1675
1644
1544
4,000
82
1628
1596
1342
8,000
79
1570
1416
1130
12,000
76
1286
1130
905
16,000
72
994
867
700
20,000
69
718
626
551
3000
0
86
1907
1876
1768
4,000
81
1860
1827
1552
8,000
78
1801
1635
1326
12,000
74
1497
1329
1087
16,000
71
1185
1050
873
20,000
68
892
798
719
Figure 5-8. Maximum Rate of Climb, Maximum Continuous Power