SECTION 9
CESSNA
PLACARDS AND MARKINGS
MODEL 162
GARMIN G300
U.S.
POWERPLANT AND ELECTRICAL INSTRUMENT
MARKINGS
Powerplant and electrical instrument markings and their color code
significance are shown in Figure 9-3. Operation with indications in the
red range is prohibited. Avoid operating with indicators in the yellow
range.
POWERPLANT AND ELECTRICAL INSTRUMENT MARKINGS
Figure 9-2
INSTRUMENT
RED
(LOWER
WARNING)
YELLOW
(LOWER
CAUTION)
GREEN
(NORMAL
OPERATING
RANGE)
YELLOW
(UPPER
CAUTION)
RED
(UPPER
WARNING)
Tachometer
(RPM)
----
----
2000 to 2750
RPM
2750* to 3500
RPM
Oil
Temperature
(OIL °F)
----
0 to 75°F
75 to 220°F
220 to 240°F
240* to 265°F
Oil Pressure
(OIL PSI)
0 to 10 PSI
10 to 30 PSI
30 to 60 PSI
60 to 100 PSI 100* to 140 PSI
Exhaust Gas
Temperature
(if installed)
(EGT °F)
----
----
1000 to 1600°F
White Advisory
Carburetor
Temperature
(CARB °F)
5 to 40°F
Battery
Current
(AMPS)
-35 to 35
White Advisory
Bus Voltage
(VOLTS)
-30 to 12.5
12.5 to 15
15 to 16
16 to 30
*Maximum operating limit is lower end of red.
162PHUS-00
9-4
Summary of Contents for 162 SKYLANE
Page 2: ......
Page 4: ......
Page 18: ......
Page 20: ......
Page 52: ......
Page 54: ......
Page 72: ......
Page 74: ......
Page 104: ......
Page 112: ...SECTION 5 CESSNA PERFORMANCE MODEL 162 GARMIN G300 U S Figure 5 1 162PHUS 00 5 10 ...
Page 114: ...SECTION 5 CESSNA PERFORMANCE MODEL 162 GARMIN G300 U S Figure 5 3 162PHUS 01 5 12 ...
Page 115: ...CESSNA SECTION 5 MODEL 162 PERFORMANCE GARMIN G300 U S Figure 5 4 5 13 162PHUS 01 ...
Page 116: ...SECTION 5 CESSNA PERFORMANCE MODEL 162 GARMIN G300 U S Figure 5 5 162PHUS 01 5 14 ...
Page 117: ...CESSNA SECTION 5 MODEL 162 PERFORMANCE GARMIN G300 U S Figure 5 6 162PHUS 01 5 15 ...
Page 118: ...SECTION 5 CESSNA PERFORMANCE MODEL 162 GARMIN G300 U S Figure 5 7 162PHUS 01 5 16 ...
Page 124: ......
Page 206: ......
Page 232: ......
Page 234: ......
Page 242: ......