FIGURE 36
9. If Autoclose has been selected, set Autoclose
timer potentiometer to suit. Clockwise
increases time (range 5-30 seconds).
It is always recommended to have
infrared safety beams fitted when using
the Autoclose feature.
FIGURE 37
Set motor polarity
10. Identify status
LED, which will give
information on gate status, whether gate is
open, closed, etc.
FIGURE 38
11. Set the polarity of each motor by triggering
the control card, making sure that the gate
direction for each leaf corresponds with the
status LED.
12. Swap motor wires on the control card to give
correct motor rotation.
page 29