14. Controller features
Inherent safety features
Safety (Collision sensitivity)
If the gate is obstructed, the internal collision circuitry will activate the gate whether opening or
closing to just stop.
The response of the system to a collision will vary according to the sensitivity level that has been
set. There are two potentiometers, one for setting the gates while opening and the second while
closing.
Clockwise adjustment reduces the sensitivity and increases the push force.
Collision count
A counter monitors the number of collisions that the gate experiences before the gate reaches
the fully closed position. If the value exceeds a preset value of four, the controller shuts down
for a period of two minutes. A valid trigger received after this shut-down period will reset the
system.
As an indication, the status LED will flash four times every two seconds. The multiple collision
fault indication will continue to flash indefinitely or until a valid trigger has been received.
Selectable features
Autoclose
Autoclose status
The Autoclose feature when turned on, has the function of automatically closing the gate after
an adjustable autoclose time.
Autoclose time
A potentiometer is provided on the controller to adjust the Autoclose time between five and
thirty seconds.
Autoclose override
It is possible for the user to temporarily turn off Autoclose. To activate Autoclose override,
press
and hold
the button of the remote or the gate intercom (any device connected to the TRG
input) for at least three seconds. Release the button. The gate will open fully and stay open.
The gate response will be to start opening on the first TRG trigger, and then to stop as soon as
the Autoclose override feature is activated. On clearing of the TRG input, the gate will continue
opening until fully open. The Autoclose feature is now off and the gate will remain open
indefinitely.
The next signal received on TRG will clear the Autoclose override feature, close the gate, and
set the Autoclose feature back to normal.
page 32
Input features
Gate trigger - Modes of Operation (TRG)
The CP77 supports three Modes of Operation:
Standard, Condominium
and
PIRAC
.
However, the gate motors rely on a mechanical endstop to stop the gate in the closed position
and the controller must be set so that they shut off when the gates reach these limits. This
limits the system to STANDARD Mode of Operation.