Open limit contact for slave motor
. The contact must be normally-open.
The contact is wired between this point and common.
Closed
limit contact for slave motor
. The contact must be normally-
open. The contact is wired between this point and common. Not used if a
closed mechanical endstop is used to stop the gate.
Auxiliary supply for external accessories such as radio receivers, safety
beams, etc. This is a 24V DC supply, maximum current 1.5A.
Solenoid strike
. A solenoid strike lock can be connected between 24V and
SOL. Note that the maximum current draw allowed for the lock is 2A.
Should the solenoid lock exceed this current rating it is necessary to use an
interposing relay. If fitting a magnetic lock an interposing relay must be
fitted to facilitate a normally-closed contact to drive the lock.
Input from charger transformer for battery charger circuit. 28-32V AC
mains, approximately 30V AC.
Pillar light connection
. These two terminals provide a normally-open
potential-free contact, which is generally used to switch on a Pillar Light
(Courtesy Light). This contact is fuse-protected – 5A. The contact is
activated for a period of two minutes each time the gate is operated. Using
the LIT input referred to above, the
light
contacts can be energized
independently of the operation of the gate.
The
common
termination point. All trigger signals, etc. have their return
path to one of the COM terminals.
Motor output – connects to the
blue
and
brown
slave motor wires.
Negative 24V battery connection.(Battery terminal normally indicated as -
or
black
)
Positive 24V battery connection.(Battery terminal normally indicated as +
or
red
).
Motor output – connects to the
blue
and
brown
master motor wires.
Two 12V batteries, wired in series, must be used in this circuit.
Ignore the fact that the control card is marked 12V. The model
CP77/24V is modified for a 24V output.
Ignore the fact that the control card is marked 15V. The model
CP77/24V is modified for a 30V AC input.
page 36
SLO
SLC
12V
SOL
15V/15V
LIGHT
COM/COM
SLAVE/
SLAVE
MASTER/
MASTER
BATTERY-
Summary of Contents for BENINCA IT24N
Page 1: ...UNDERGROUND SWING GATE OPERATOR IT24N BENINCA installation manual IT24N...