page 98
page 98
www.centsys.com
13.2.2. Attaching the drive linkage unit to the spike module
Take note of the orientation of the sandwich plate to the linkage unit before
fi
xing them to the spike module assembly (Section 13, Figure 23).
Sandwich
plate
Linkage
unit
M12 Nut
M12x25 bolt
Spike
module
To assist with the alignment and adjustment of the shafts, loosen (but do not
remove) the bolts on all of the bearing housings.
STEP 3
Using six M12x25 bolts,
fi
x one spike module to another (Section 13, Figure 25).
FIGURE 25
Ensure that the shafts align
throughout the assembly
Bearing housing
M12x25 Bolt
Spike Module
M12 Nut
FIGURE 23
FIGURE 24
STEP 1
STEP 2
RHS FLUSH MOUNT - SIMILAR DIRECTION OF TRAVEL
SECTION 13