This document describes the basic steps to follow when installing the
fl
ush-mountable
CLAWS
Spikes driven directly from a SECTOR II Barrier by a “push-pull” linkage system.
The installation described in this document is a 2.5 meter installation which utilises
modules of 1.5 and 1.0 meters.
The installation of the
CLAWS
Spikes requires a minimum of two persons.
12.1. Installation Con
fi
gurations
The
fl
ush-mountable
CLAWS
Spikes can be installed in four di
ff
erent con
fi
gurations.
The con
fi
guration is dependent on two factors:
• Orientation of installation
• Direction of spike impact
FIGURE 2. RHS CONFIGURATION
FIGURE 3. LHS CONFIGURATION
12.1.1. Orientation of Installation
The orientation of installation is described as the side at which the drive linkage is
installed when approaching the
CLAWS
Spikes. In other words, when driving up to the
CLAWS
Spikes, in the correct direction for tra
ffi
c
fl
ow, and the drive is installed on the
right-hand side of the vehicle, it’s deemed a right-hand installation. And when driving up
to the
CLAWS
Spikes, in the correct direction for tra
ffi
c
fl
ow, and the drive is installed on
the left-hand side of the vehicle, it’s deemed a left-hand installation.
INTRODUCTION
SECTION 12
12. Introduction
Summary of Contents for CLAWS