Maximum Current Rating
1.5 A/CH or 4.0 A max total all 4 lighting channels, whichever is less.
Channel Output Voltage
Unregulated; >98% of supply voltage
Channel Output Mode
Current sinking only
Communication Port
RJ45 connector. 100BaseT Ethernet. TCP/IP protocol. Control via Web-based GUI
or TCP/IP command set
Indicator Functions
Power On
Trigger Activity
Ethernet
–
network connection
Ethernet
–
network activity/fault
General Fault
Fault
Firmware
User upgradeable via Web-based GUI (included)
Sequence Timing
User programmable via Web-based GUI (included) and TCP/IP command set
Default: Photometric Stereo (PMS) 4 frame sequence
40 fps operation, 25 mS frame, 20ms Strobe Width (exposure), 15 mS
camera trigger
Timing Resolution
Maximum Trigger rate: 10,000 fps (100 µS)
Minimum output signal width: 100 µS
Maximum delay trigger to start first frame: 50 µS
Timing resolution: 1 µS
Channel skew + jitter: <= 10 µS
Frame Time
100 µS
–
2000 S; Time for each frame in a sequence
Strobe Width
100 µS - 2000 S; Independently selectable CH1 - CH4. Must be < frame time
Camera trigger Width
100 µS - 2000 S; Must be < frame time
Trigger Type
Triggered One-shot (default), Triggered Continuous, Free-run (continuous non-
triggered)
Trigger Event
Triggers based off Recipe, Sequence, or Frame.
Note: Trigger Type must be set to One-Shot
Trigger Delay
If enabled - 2 µS - 65 mS @ 1µS resolution or 2 mS - 16 sec @ 1mS resolution
(optional)