![background image](http://html1.mh-extra.com/html/ccs/lss-2404/lss-2404_user-manual_2575900061.webp)
LSS-2404
57 |
P a g e
F.
Multi Shot Imaging Examples
Example 1
How to set up a program that has: one PMS image, 3 normal ring light images, and one image that only
illuminates the left quadrant of the light (lighting block 2). During execution only one trigger is needed to run the
entire recipe. The inspection is stationary but requires the recipe to have a capture time of 110 ms.
Recipe Settings
Trigger Type: One Shot
Trigger Event: Series
Sequence 1: will have a total capture time of 40 ms, 10 ms for each frame.