Safety Precautions
Read this section before using the LSS-2404. Always observe the following safety precautions. If in doubt,
contact CCS America, Inc. The following symbols are used in this guide:
Warning:
Read the instructions to understand the possible hazards.
Warning:
Surface may get hot.
Warning:
Possible hazardous voltage.
Refer to the text in this section for precautions you should take whenever the above symbols appear in this
guide.
Heat
Ensure that the LSS-2404 is mounted correctly (see Mounting the LSS-2404),
and that you do not exceed any of the ratings for the unit (see Specifications
and Ratings).
At its maximum ratings, the LSS-2404
’s enclosure can
not exceed 50 °C,
which is sufficient to cause a burn if touched.
Place the unit in a position where personnel cannot accidentally touch it and
ensure there is a free flow of air around the unit.
Electrical
The LSS-2404 produces high energy pulses.
Take care to connect the outputs correctly and protect the output wiring and
load from any short-circuits.
When switched off, energy may remain stored in the 2404 for a few seconds.
Use caution with connections immediately after shut down.
The 2404 does not have complete tracking isolation of input and output.
Transients caused by inductive loads must be suppressed externally to the 2404.
The LSS-2404 is a Class B device intended for industrial or commercial
applications, even though it does conform within Class A emission limits which
are stricter for residential use. If any unwanted interference does occur, cable
shielding, grounding, and the product installation should be reviewed by the
user to restrict emissions to a level that prevents interference with broadcast
transmissions.
General
The LSS-2404 must not be used in an application where its failure could be a danger
to personal health or damage to other equipment.