15.
TROUBLESHOOTING GUIDE
Air loss from the Accelair 2 machine is greater than normal:
o
Ensure the correct changeable parts are fitted for the fibre
and tube being used.
o
Check air seal beneath the lower blowing plate; replace if
necessary.
o
Check blowing plate seal; replace if necessary.
Little or no air-flow is exiting the tube:
o
Check compressor output (refer to manufacturers handbook)
o
Installation route may be too complex for installation.
o
Route length is too long.
o
There may be a partial blockage in the tube.
o
The tube may be crushed somewhere along the route.
Fibre ‘rides’ out from between the drive wheels:
o
Larger tyres may be needed for improved guidance – follow
section 10 for details on changing tyres.
Fibre installation speed is very slow:
o
Static build up – switch the compressor from dry air to by-
pass mode (if available).
o
Moisture build up – ensure compressor is running in dry air
mode or check dryer operation.
Fibre buckles often:
o
Installation route may be too complex for installation.
o
The tube route may be damaged/blocked.
o
Increase air pressure if possible.
o
Manually slow the installation speed slightly.
Machine won’t run – Error displayed:
o
Check plates fitted to machine. If non-buckle plates are being
used ensure the machine is set to non-buckle operation, see
page 20.