Page
31
of
41
10.
PROCEDURE FOR REPLACING TUBE CLAMP
INSERTS AND INFEED GUIDES
Various tube clamp inserts and infeed guides are available for the C-1800
Accelair 2 to allow the use of different tube and fibre sizes. Both the tube
clamp inserts and infeed guides are retained using 2 off M3 cap screws each
and require the use of the 2.5mm allen key.
Remove all retaining screws and remove the inserts/guides.
Replace inserts/guides of suitable size into the machine and tighten
the retaining screws firmly but take care not to damage any
aluminium threads.
Store the removed inserts/guides in the bag provided and in the
designated area of the carry case to avoid loss or damage.
Retaining
Screws