8.
PROCEDURE FOR CHANGING THE BLOWING
PLATES
The C-1800 Accelair 2 uses two types of blowing plates. One type is for use in
conjunction with the buckle functionality and one without. The buckle plates
use 4 off M3 cap screws each to retain them into the machine; the non-
buckle plates use 3 off each. The supplied 2.5mm allen key will be required
for removal.
Remove all retaining screws and lift the plates out of the machine.
Inspect the condition of the air seal beneath the lower plate and
replace if necessary (photo overleaf).
Replace plates of suitable size into the machine and tighten the
retaining screws firmly but take care not to damage the aluminium
threads.
Retaining
Screws