SECTION 2 - CONTROLS, INSTRUMENTS AND OPERATION
2ï92
DIAGNOSIS OUTPUT
Outputs for solenoids and other sources can be
displayed, and used by Dealers to make adjustments.
These can be viewed through the diagnosis screen
using the diagnosis output icon (1), and by use of the
soft key, or touch screen.
An example of an output diagnosis is operating lights
as shown here where the light can be viewed as
digital status.
Shown below is the list of outputs that can be checked
by selecting the outputs field (1) using the key pad or
rotary encoder:
Main power relays
K1, K2
Main power relay
K3
Knotter fans
K21
Flashing light
K11
Operating lights
K12
Grease pump
K22
Accessory 2
K14
Density valve
Y2
Chain oiling pump
K13
Pick-up stop (where fitted)
Y4
Bale electric trip system (where fitted)
K15
Stuffer light
K31
Density sensor
Bale weigh system (where fitted)
Y2
201
202
Summary of Contents for 84336239
Page 33: ...Table of Contents xxvii ...
Page 34: ......
Page 84: ...SECTION 2 CONTROLS INSTRUMENTS AND OPERATION 2ï26 One next to the service ladder 43 ...
Page 86: ...SECTION 2 CONTROLS INSTRUMENTS AND OPERATION 2ï28 46 ...
Page 91: ...SECTION 2 CONTROLS INSTRUMENTS AND OPERATION 2ï33 MONITORS 55 56 57 58 ...
Page 134: ...SECTION 2 CONTROLS INSTRUMENTS AND OPERATION 2ï76 FIELD SETTINGS 163 164 165 166 ...
Page 137: ...SECTION 2 CONTROLS INSTRUMENTS AND OPERATION 2ï79 MEMORY 169 170 171 172 ...
Page 166: ...SECTION 2 CONTROLS INSTRUMENTS AND OPERATION 2ï108 Knotter 230 231 232 233 ...
Page 177: ...SECTION 2 CONTROLS INSTRUMENTS AND OPERATION 2ï119 NOTE ...
Page 178: ......
Page 179: ......