48
3) External Control for Input / Output Interface
■
External input
Pin No.
SIGNAL LINE NAME
DESCRIPTION
24, 25
GND (Input common)
External input common
16
ZERO input
ZERO key operation
17
TARE input
TARE key operation
18
START input
Used as START key in batching operation
19
STOP input
Used as STOP key in batching operation
20 “*”
input
“*” is used in various way
(Set this key in SET mode F23)
21 ENTER
input
“*” is used in various way
(Set this key in SET mode F24)
22, 23
Buffer
Enable to add the Key function
■
External output (Relay contact)
Pin No.
SIGNAL LINE NAME
Pin No.
SIGNAL LINE NAME
3
Zero band signal output (Out 1)
7
High limit signal output (Out 5)
4
Optional preliminary output (Out 2)
8
Low limit signal output (Out 6)
5
Preliminary output (Out 3)
9
Finish signal output (Out 7)
6
Final weight signal output (Out 4)
10
Stable signal output (Out 8)
11, 12
Output common
■
External control I/O circuit
Summary of Contents for CI-6000A Series
Page 1: ...2 ...
Page 8: ...9 4 Measure of Appearance ...
Page 22: ...23 5 Sealing Method Sealing method of cal switch Sealing method of Load Cell Connector ...
Page 51: ...52 Normal Batching Diagram Loss in Weight Batching Diagram ...
Page 52: ...53 USER PROGRAM CONTROLMODE Normal Batching ...
Page 54: ...55 USER PROGRAM CONTROLMODE Loss in Weight ...
Page 56: ...57 AUTOMATIC PROGRAM CONTROLMODE Normal Batching ...
Page 58: ...59 AUTOMATIC PROGRAM CONTROLMODE Loss in Weight ...
Page 71: ...72 MEMO ...
Page 72: ...73 MEMO ...
Page 73: ...74 MEMO ...
Page 74: ...75 ...