![CAS CI-6000A Series Manual Download Page 16](http://html1.mh-extra.com/html/cas/ci-6000a-series/ci-6000a-series_manual_2565930016.webp)
17
CAL 1
FUNCTION : Maximum Capacity Set (Range : 1 ~ 99,999)
KEY
DISPLAY
DESCRIPTION
C = 05000
5000 kg
C = 0500.0
500.0 kg(First decimal point)
:
Increase or decrease
of number
:
Shift of cursor position
ENTER :
Save and go to next
menu
C = 050.00
50.00 kg (Second decimal point)
Note 1. The maximum capacity means the maximum weight of the indicator.
Note 2. The max. weight is changed depending on the decimal point.
CAL 2
FUNCTION : Minimum Division Set (Range : 0.001 ~ 50)
KEY
DISPLAY
DESCRIPTION
d = 1
1 kg
d = 0.2
0.2 kg (First decimal point)
d = 0.05
0.05 kg (Second decimal point)
:
Increase or decrease
of number
ENTER :
Save and go to next
menu
d = 0.001
0.001 kg (Third decimal point)
Note 1. The minimum division means the value of one division.
Note 2. The value of one division is changed depending on the decimal point.
Note 3. External resolution is obtained by dividing the maximum capacity into the min. division.
Set the resolution to be within 1/10,000.
If it is over 1/10,000, error message "Err 20" is displayed
Summary of Contents for CI-6000A Series
Page 1: ...2 ...
Page 8: ...9 4 Measure of Appearance ...
Page 22: ...23 5 Sealing Method Sealing method of cal switch Sealing method of Load Cell Connector ...
Page 51: ...52 Normal Batching Diagram Loss in Weight Batching Diagram ...
Page 52: ...53 USER PROGRAM CONTROLMODE Normal Batching ...
Page 54: ...55 USER PROGRAM CONTROLMODE Loss in Weight ...
Page 56: ...57 AUTOMATIC PROGRAM CONTROLMODE Normal Batching ...
Page 58: ...59 AUTOMATIC PROGRAM CONTROLMODE Loss in Weight ...
Page 71: ...72 MEMO ...
Page 72: ...73 MEMO ...
Page 73: ...74 MEMO ...
Page 74: ...75 ...