8. Calibration Mode
1) How to enter the Calibration Mode.
Open the front cover of indicator and set SW1 DIP1 to on.
At this time, message is shown on the display and
is started.
After done and off the SW1 DIP1, back to the weighing mode.
2) Availabe keys.
KEY : Change the set value.
key increases set value and
key decreases set value.
KEY : Change the position of cursor.
key moves one digit to right,
key moves one digit to left.
ENTER KEY : The program is moved into next menu.
3) Calibration menu(CAL1~CAL7)
CAL 1 : Maximum capacity
CAL 2 : Minimum division
CAL 3 : Setting Weight
CAL 4 : Zero calibration
CAL 5 : Span calibration
CAL 6 : Check Micro Span calibration
CAL 7 : Weight Factor