![CAS CI-6000A Series Manual Download Page 41](http://html1.mh-extra.com/html/cas/ci-6000a-series/ci-6000a-series_manual_2565930041.webp)
42
⑥
Options
F55
FUNCTION : Select of Option
DISPLAY
DESCRIPTION
F55 0
Do not use
F55 1
Analog Out(Option – 1,2)
Set value
( 0 , 2 )
F55 2
BCD Out(Option – 3)
F56
FUNCTION : Output Logic – BCD Out
DISPLAY
DESCRIPTION
F56 0
Positive Logic
Set value
( 0 , 1 )
F56 1
Negative Logic
F57
FUNCTION : Analog Output Adjustment at Display Zero
DISPLAY
DESCRIPTION
L 00000
0mA, 0V
L 04000
4.000mA, 2V
Set value
( 0~4000 )
L 04015
4.015mA, 2.007V
F58
FUNCTION : Analog Output Adjustment at Maximum Capacity
DISPLAY
DESCRIPTION
H 10000
10mA, 4.16V
H 20000
20.000mA, 8.33V
Set value
( 0~24000 )
H 24000
24.000mA, 10V