38
21. Clock-CAL (CAW series only)
Automatic span calibration is initiated when
tCAL-on
is selected and the
time set at
tCAL t1
-
t3
in the measuring mode is reached.
Two Minute Warning
During operation, the weight symbol blinks to indicate that the above
condition has occured and span calibration will start in approximately two
minutes. To skip the span calibration, press the
POWER/BRK
key while the
weight symbol is blinking.
Procedure
(1) From the mass display, press the CAL/MENU key several times.
When
"SEttinG"
is displayed, press the
→
O/T
←
key.
(2) Press the CAL/MENU key several times to display
"tCAL:**."
The
** indicate the current setting for automatic span calibration.
"on"
indicates that the function is active and
"oF"
indicates that the
function is turned off.
(3) Press the
→
O/T
←
key to change the setting.
(4) Each time CAL/MENU is pressed,
tCAL-oF"
or
"tCAL-on"
is
displayed. The current setting is displayed with the stability symbol.
When the desired item is displayed, press the
→
O/T
←
key to
change the setting, or press the POWER/BRK to return to
"tCAL:**."
(5) When
"tCAL:**"
is displayed, press and hold the POWER/BRK
key to return to the mass display.
22. Clock-CAL STARTING TIME (CAW series only)
Span calibration is automatically conducted when
"tCAL-on"
is selected and
one of the set times is reached.
Up to three separate calibration times may be entered. Use the 24-hour
system to designate the hour and minute of the starting time. When all the
digits are displayed as "_", the time setting is cancelled.
Procedure
(1) From the mass display, press the CAL/MENU several times. When
"SEttinG"
is displayed, press the
→
O/T
←
key.
(2) Press the CAL/MENU key several times. When
"tCAL t1", "tCAL
t2" or "tCAL t3"
is displayed, press the
→
O/T
←
key. The weight,
[MENU] and # symbols are displayed to indicate numeric value