![background image](http://html.mh-extra.com/html/carrier/ziton-zp3/ziton-zp3_user-manual_2562680020.webp)
12
ZP3 Fire Panel User Guide
Fire indicator
The Fire indicator illuminates when any fire alarm is received by, or is currently
present, in the system. The indicator flashes for a new alarm, and becomes
steady after an alarm has been accepted. New alarms must be responded to
immediately. Other indicators identify the location of the alarm, and are described
later in this document. This indicator is normally off.
Fault indicator
The Fault indicator illuminates when any fault alarm is received by, or is currently
present, in the system. Other indicators identify the location and type of fault.
Fault alarms have different levels of severity; some may take the complete
system out of operation, some may take only a small part of the system out of
operation, while others may simply report a condition that needs attention. Refer
to “
Types of fault” on page 24 for more details. This indicator is normally off.
Disabled indicator
The Disabled indicator illuminates when any part of the system (for example, a
zone, a fire sensor, a sounder, or a connection to the fire brigade) is deliberately
disabled. This might be done for a number of reasons, for example, to allow part
of a building to be renovated, for maintenance, or to allow people to smoke in a
meeting room. Other indicators identify the location of the disabled devices;
these will be described later in this manual. This indicator is normally off.
Other indicator
The Other indicator illuminates to identify the presence of any alarm that does
not fall into one of the above groups. For example, this could be an alarm that a
fire door is unlocked, or that air conditioning is shut down, or a prealarm, etc.
Other indicators identify the nature of the alarm, and are described later in this
manual. This indicator is normally off.
Zonal fire indicators
See Figure 5 on page 13. In addition to the common alarm indicators, by default
alarms are indicated by means of zonal fire indicators, and by means of text
messages on the LCD display, which also shows other information. Alternatively
the LED can be programmed as required. For more information, see “I/O
Mapping” in the
Installation, Commissioning and Maintenance Manual
(P/N 503-
1160ZE-I).
Zonal fire indicators are red, and are located on the left side of the fascia. When
an alarm is received from a sensor, the Zone indicator illuminates to identify
which zone has initiated the alarm. This immediately identifies the location of the
fire. The Zone indicator flashes for a new alarm, and becomes steady after an
alarm has been accepted. The zonal fire indicators make it possible to quickly
determine the zones in an alarm condition, and to identify which are new alarms
and which have been previously accepted. Zone indicators are normally off.