T-362
2–4
Controllers will be factory-equipped with the latest version of operational software, but will NOT be configured for a
specific model number and will need to be configured at the time of installation or sale.
2.5.20
Condenser Grille
Condenser grilles are direct bolted.
2.5.21
Emergency Bypass
The optional Emergency Bypass switch (EB) functions to bypass the controller in the event of controller failure.
2.5.22
XtendFRESH
XtendFRESH™ is an OEM option that helps slow the ripening process by removing ethylene and simultaneously
controlling CO
2
and O
2
levels in multiple combinations.
Procedures and technical information related to the XtendFRESH™ controlled atmosphere system can be found in
the
, located in the Literature section of the Container Refrigeration website. To find
the manual from the Literature section, click on Options > XtendFRESH.
2.5.23
TripWise
TripWise™ is a new premium option available for PrimeLINE units. TripWise is software logic that runs in the
background during every voyage and will let you know whenever a standard pre-trip inspection (PTI) is needed.
Refer to
for more detail on the TripWise option.
2.5.24
FuelWise
FuelWise™ is a power-saving option available for PrimeLINE units. FuelWise software works by dynamically
cycling the refrigeration system on and off to save energy while still maintaining temperature /- 0.25
degrees Celsius of setpoint on an hourly average.
2.5.25
QUEST
QUEST (Quality and Energy Efficiency in Storage and Transport) power-saving mode available for PrimeLINE
units. QUEST reduces energy requirements by up to 50 percent while reducing emissions related to power
consumption.