12. Prepare the required amount of epoxy resin per instructions on the package and place on the cardboard and
replace the cap onto the epoxy container after use.
NOTE
When the temperature is below 10°C (50°F), warm up the affected area prior to the repair using a heat
gun. Do not use an open flame.
13. Place mixed epoxy onto the leak point using wooden picks (while the unit is under vacuum).
14. The vacuum pump should be able to pull the epoxy through the cut area to form a shape that works as a plug.
15. Apply additional mixed epoxy with the application tool to the leak area and along the cleared fin section.
Make sure that resin is sucked into the opening.
16. Place mixed epoxy on the aluminum wrapper and place the aluminum wrapper over the leak area.