![Carrier PrimeLINE 69NT40-561-200 Operation And Service Manual Download Page 134](http://html.mh-extra.com/html/carrier/primeline-69nt40-561-200/primeline-69nt40-561-200_operation-and-service-manual_2561447134.webp)
T-362
7–14
Tools Required:
• Screw driver set
• Standard hand tools
• Needle nose pliers (long nose)
• 35 degree bent long nose pliers
• Duckbill pliers
• Tube brush (soft bristle)
• Emery cloth
• Disposable gloves
• Utility knife
• Protective goggles
• Vacuum pump
• Gauge manifold
• Alcohol
• Water
Parts Required:
Procedure:
NOTE
This repair is only a limp home repair. The coil should be replaced at the earliest convenience.
1. Locate the suspect leak using an electronic leak detector or liquid soap (looking for bubbles). If required,
pressurize the unit with Nitrogen confirming the leak location.
NOTE
When refrigerant escapes, oil that also escapes will typically result in a wet looking area and or heavy
concentrations of dirt sticking to oil. These are usually good indicators of where to begin a check.
2. Remove the refrigerant and or any nitrogen used for leak checking from the system.
Item
Part Number
Description
Quantity
76-00893-00
MCHE Repair Kit
1
1
02-00312-00
3M SCOTCH-WELD DP100 Epoxy B/A Gray
1
2
58-05127-00
Dispensing Gun For 1.69 oz Cartridges
1
3
58-05127-01
Plunger, 1:1 Mix Ratio
1
4
58-05127-02
Mixer Nozzles, 1.69 oz Cartridges
3
5
68-18212-00
Plate, Aluminum
3
6
58-05127-03
Emery Cloth Block-Shaped 180 Grit, 1” x 7”
2
7
58-05127-04
Zip-Press Polyethylene Bag 2 Mil Thick, 2” x 2”
1
8
58-05127-05
Documents Holder, Press to Close, 10” x 8-1/2”
1
9
58-05127-06
Nonmarring Picks, Wood, Flat Tip/Point Tip, 7" Length
1
10
98-02667-00
Instruction Sheet
1