3–15
T-362
Figure 3.11 Refrigeration Circuit Schematic - Standard Operation
1) Compressor
2) Discharge Service Valve
3) Discharge Pressure Transducer (DPT)
4) Condenser
5) Receiver
6) Receiver Sight Glass
7) Fusible Plug
8) Receiver Liquid Level / Moisture Indicator
9) Liquid Line Service Valve
10) Filter Drier
11) Economizer
12) Economizer Solenoid Valve (ESV)
13) Economizer Expansion Valve (EXV)
14) Economizer Expansion Valve (EXV) Sensing Bulb
15) Economizer Connection
16) Electronic Expansion Valve (EEV)
17) Evaporator
18) Evaporator Temperature Sensor (ETS1)
19) Evaporator Temperature Sensor (ETS2)
20) Digital Unloader Valve (DUV)
21) Evaporator Pressure Transducer (EPT)
22) Suction Pressure Transducer (SPT)
23) Suction Service Valve
- - - - -
Discharge
Vapor
Liquid
Saturated
Mixture
Suction
Vapor
Summary of Contents for PrimeLINE 69NT40-561-200
Page 12: ......
Page 18: ......
Page 100: ......
Page 182: ......
Page 184: ...T 362 8 2 ELECTRICAL WIRING SCHEMATIC AND DIAGRAMS Figure 8 2 Schematic Diagram ...