5–10
Checking TripWise Status
To check the status of the container, press the PRE-TRIP key on the keypad. The message “SELCt | PrtrP” will
appear on the display module, alternating with a TripWise status message described below:
Pressing the ENTER key while | “SELCt | “PrtrP” | is displayed will enter into the Pre-trip test menu. Pressing the
Arrow keys will navigate through the standard PTI test selections menu.
Enabling or Disabling TripWise Option
1. Press the CODE SELECT key on the keypad.
2. Use the Arrow keys to bring up code Cd65 in the display.
3. Press the ENTER key. The display will show either “-----”, “OFF” or “ON”.
NOTE
If “-----” is displayed, the TripWise function option is not active on the unit. To add this option to the unit,
the equipment owner would need to contact their Regional Carrier Sales Manager.
4. Use the Arrow keys to toggle between “ON” and “OFF” and then press the ENTER key to select the desired
option.
5. If “ON” is selected, the display will show “dAYS”. This is the expiration time (2 through 365 in 1 day
increments). Use the Arrow keys to change the parameter and then press the ENTER key to confirm.
NOTE
The expiration interval is the total maximum days allowed between the running of each test. For exam
-
ple, if days are set to 30 and the low speed evaporator fan test has not run within those 30 days, the
TripWise expired message will be displayed. If the TripWise expired message is displayed, it is recom
-
mended to Pre-trip the unit following customer specific guidelines prior to the next trip.
TripWise Status Event
A TripWise status event will be recorded in the DataCorder recorder when the PTI is selected. In the current
DataLINE software release, the event will show the status of the unit.
Figure 5.4 TripWise Status in DataCorder
| “trIPW” | “OFF” |
The TripWise option is turned off.
| “trIPW” | “EX” | (Expired) It is recommended to pre-trip the unit prior to the unit's next trip following
customer-specific guidelines.
| “trIPW” | “PASS” |
The container should be ready for use after the operator has conducted a
visual inspection. Standard PTI is not required.
| “trIPW” | “CHECK” |
If any TripWise test(s) execute and do not meet the pass / fail requirements,
It is recommended to pre-trip the unit following customer-specific guidelines
prior to the unit's next trip.
COOL
HEAT
DEFROST
IN RANGE
ALARM
SUPPLY RETURN
SETPOINT/Code
AIR TEMPERATURE/Data
COOL
HEAT
DEFROST
IN RANGE
ALARM
SUPPLY RETURN
SETPOINT/Code
AIR TEMPERATURE/Data
Summary of Contents for PrimeLINE 69NT40-561-200
Page 12: ......
Page 18: ......
Page 100: ......
Page 182: ......
Page 184: ...T 362 8 2 ELECTRICAL WIRING SCHEMATIC AND DIAGRAMS Figure 8 2 Schematic Diagram ...