6–5
T-362
6.9 Microprocessor Malfunction
Will not control
Incorrect software and/or controller configuration
Check
Defective sensor
Defective wiring
Check
Low refrigerant charge
6.10 No Evaporator Air Flow or Restricted Air Flow
Evaporator coil blocked
Frost on coil
Dirty coil
No or partial evaporator air
flow
Evaporator fan motor internal protector open
Evaporator fan motor(s) defective
Evaporator fan(s) loose or defective
Evaporator fan contactor defective
Replace
6.11 XtendFRESH not Operating
Vent not opening
Unit not Configured for XtendFRESH Operation
No action
Cd43 in Off mode
Enable Fresh Mode at
Wiring disconnected
Check wiring
Unable to calibrate CO
2
sensor
CO
2
outside of acceptable levels
Check
Check CO
2
sensor
Enable Test Mode at Cd43.
Code 44 displays “- - - - - “
Unit not Configured for XtendFRESH Operation
No action
Check CO
2
sensor
Enable Test Mode at Cd43.
6.12 Electronic Expansion Valve Malfunction
Low suction pressure
Incorrect software and/or controller configuration
Check
Failed suction pressure transducer (SPT) or
evaporator pressure transducer (EPT)
Replace
Suction service valve partially closed
Open
Filter drier partially plugged
Low refrigerant charge
No evaporator air flow or restricted air flow
Excessive frost on evaporator coil
Evaporator fan(s) rotating backwards
EEV control malfunction
Failed digital unloader valve (DUV)
Replace
Loose or insufficiently clamped sensor
Replace
High suction pressure with
low superheat
Foreign material in valve
Failed suction pressure transducer (SPT) or
evaporator pressure transducer (EPT)
Replace
EEV control malfunction
Replace
Improperly seated powerhead
Ensure powerhead is
locked and in place
Condition
Possible Cause
Remedy / Reference