5–11
T-362
In DataLINE version 3.2, perform an all data download by selecting from the drop down menu “TripWise Summary”
and then select a date in “User Logged Events” as shown in the Figure below. This will generate the status / results
in a DataLINE TripWise Summary Report
Figure 5.5 Generating TripWise Summary Report
5.10.3
XtendFRESH
XtendFRESH™, setup through function code Cd43, is a controlled atmosphere option that helps slow the ripening
process by removing ethylene and simultaneously controlling CO2 and O2 levels in multiple combinations. Refer to
for detail description of Cd43 and Cd44 XtendFRESH Mode menu selections.
For detailed procedures and technical information related to the XtendFRESH controlled atmosphere, refer to the
Turning On XtendFRESH Fresh Mode:
When XtendFRESH is in Fresh Mode, all XtendFRESH operations are enabled and setpoints for CO2 and O2 are
confirmed.
1. Press the CODE SELECT key.
2. Use the Arrow keys to bring up Cd43 and press the ENTER key.
3. Use the Arrow keys to bring up “FrESh” and press ENTER.
4. The display will show | “CO2SP” | “#” |, where # is the CO2 setpoint value. Use the Arrow keys to select a
CO2 setpoint and press ENTER to confirm. Or, just press ENTER to keep the originally displayed value.
The CO2 setpoint is the maximum level of CO2 allowed for the cargo. The range is 0% to 19% in 1%
increments, with a default setting of 5%.
5. The display will show | “O2 SP” | “#” |, where # is the O2 setpoint value. Use the Arrow keys to select an O2
setpoint and press ENTER to confirm. Or, just press ENTER to keep the originally displayed value.
The O2 setpoint is the minimum level of oxygen allowed for the cargo. The range is 3% to 21% in 1%
increments, with a default setting of 10%.
Turning Off XtendFRESH Fresh Mode:
When Off mode is active, all XtendFRESH operations will be disabled. The XtendFRESH vents will be closed and
the scrubber will remain off. This will be the default mode anytime a frozen mode of operation has been selected.
Whenever a frozen setpoint is selected, the current XtendFRESH setting will be saved.
1. To manually turn XtendFRESH Mode Off, press the CODE SELECT key.
2. Use the Arrow keys to bring up Cd43 and press the ENTER key.
3. Use the Arrow keys to bring up “OFF” and press ENTER.