T-362
4–50
In the Standard Mode, the user may configure the DataCORDER to record data using one of several standard
configurations. The standard sensor configurations are described in
.
The inputs of the six thermistors (Supply, Return, USDA #1, #2, #3 and Cargo probe) and the Humidity Sensor
input will be generated by the DataCORDER.
NOTE
The DataCORDER software uses the Supply Recorder Sensor (SRS) and Return Recorder Sensor
(RRS). While the temperature control software uses the Supply Temperature Sensor (STS) and
Return Temperature Sensor (RTS).
Generic Mode
The Generic Recording Mode allows user selection of the network data points to be recorded. The user may select
up to a total of eight data points for recording. Changing the configuration to generic and selecting which data
points to record may be done using the Carrier Transicold Data Retrieval Program. A list of the data points
available for recording follows.
1. Control mode
2. Control temperature
3. Frequency
4. Humidity
5. Phase A, B, C current
6. Main voltage
7. Electronic Expansion Valve (EEV) percentage
8. Discrete outputs (Bit mapped - require special handling if used)
9. Discrete inputs (Bit mapped - require special handling if used)
10. Ambient Temperature Sensor (AMBS)
11. Evaporator Temperature Sensor (ETS)
12. Compressor Discharge Sensor (CPDS)
13. Return Temperature Sensor (RTS)
14. Supply Temperature Sensor (STS)
15. Defrost Temperature Sensor (DTS)
Table 4–8 Sensor Configuration
Standard Config
Description
2 sensors (dCF02=2)
2 thermistor inputs (supply & return)
5 sensors (dCF02=5)
2 thermistor inputs (supply & return)
3 USDA thermistor inputs
6 sensors (dCF02=6)
2 thermistor inputs (supply & return)
3 USDA thermistor inputs
1 humidity input
9 sensors (dCF02=9)
Not Applicable
6 sensors (dCF02=54)
2 thermistor inputs (supply & return)
3 USDA thermistor inputs
1 cargo probe (thermistor input)
7 sensors (dCF02=64)
2 thermistor inputs (supply & return)
3 USDA thermistor inputs
1 humidity input
1 cargo probe (thermistor input)