background image

27

Fig. 12 — Ty

pical Low 

Volt

age

 Control 

Wiring

 Diagram (co

n

t)

1

2

3

4

5

6

7

8

9

10

11

12

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

Xnet+

Xnet-

GND

10V

10V

+5V

+24V

IN01

IN

0

2

IN03

IN

0

4

IN05

IN

0

6

IN07

IN

0

8

IN09

IN

1

0

IN11

IN

1

2

24

V

GND

OFF

ON

0

1

+1

2V

Rne

t-

Rne

t+

GN

D

LON Port 2b*

PCB1 – I/O FLEX 6126

2

4

 VAC

2

-10 VD

C

4

2

1

CO

MM

O

N

W1 RA

 (CCW)

W2 0-

10V

DC

24

 V

A

C

2-

1

0

 V

D

C

4

2

1

CO

MM

O

N

W1 RA

 (CCW)

W2 0-

10V

DC

-

+

TB7

3

2

1

HRN2

TB4

N

700/WHT

701/GRN

610/PN

K

612/YEL

614/GRA

708/WHT

707/GRN

DH

S

706/BLK

VFD

NOTE 5

616/BLU

608/BLU

635/BRN

632/RED

636/BRN

633/RED

631/VIO

63

0/OR

N

637/BRN

634/RED

MVLV

EC

ON

O

2

3

4

1

700/WHT

701/GRN

630/ORN

631/VIO

HRN

3

4

3

- +

FIEL

D Co

nn

ectio

n

Exhaust Fan

DSP

640/BLK

A

B

BP

S_S

617

BRN

- + +

+

6

56

3

8

/B

R

N

638

BRN

627

/OR

N

628

/BLU

629

/BRN

603

RED

606

BRN

639/RED

607/R

E

D

609/R

E

D

611/R

E

D

613/R

E

D

FIELD

 ALARM

Con

n

ec

tion

NC

NO

CO

M

615/R

E

D

FIELD

 Conne

ction

Fire/Sm

o

ke D

etec

tor

+

- +

FIEL

D Co

nn

ectio

n

He

at

+

1

3

2

PRES

2.7K

10K

703/WHT

702/BLK

704/RED

705

/RED

-

FIEL

D Co

nn

ectio

n

 SP

T

FIE

L

D C

o

nnect

ion IAQ

FI

EL

D Co

nn

ecti

o

n

 I

n

do

o

r RH

FIELD Connection RESET

FIELD C

o

nnection Bldg. Pressure

(Comp

ressor 1)

(Comp

ressor 2)

(Comp

ressor 3)

(C

ompre

s

sor 4

)

CDWF

S

618

BRN

BLU

BLK

WHT

BRN

2

4

3

1

607/R

E

D

609/R

E

D

611/R

E

D

613/R

E

D

615/R

E

D

616/BLU

61

9

BLU

HR

N2

A

B

CR

1

5

62

0

BRN

62

1

PNK

A

B

CR

2

6

62

2

BRN

62

3

YEL

A

B

CR

3

7

62

4

BRN

62

5

GRA

A

B

CR

4

8

62

6

BRN

709

/RED

710

/BLK

SA

T

-

A

B

CDWF

FIEL

D Co

nn

ect

io

n

 

Occupa

ncy Input

HRN

3

601

RED

604

BRN

2

1

627/ORN

628/BL

U

629/BRN

605/BRN

602/RED

a50-8464

Summary of Contents for OMNIZONE 50XJ104

Page 1: ...n working on this equipment observe precautions in the literature on tags stickers and labels attached to the equip ment and any other safety precautions that apply Follow all safety codes Wear safety...

Page 2: ...tion Optional and Field Installed Accessory Sensors Devices These units can be ordered with options and ac cessories that add functionality and control These options and accessories are used as descri...

Page 3: ...og 5K Sensor IN 10 W8 Therm Dry Water Econ Freezestat Sensor or Switch FREEZE Analog 10K 2 Sensor or Switch Closure IN 11 IW7 Therm Dry configurable Mixed Return Air Temperature MA_RA Analog 10K 2 Sen...

Page 4: ...signal 1 to 5 vdc linearly The sensor s range is 0 to 550 psig Water Valve s Control Variable Building Waterflow Systems Variable waterflow configurations use only one water valve in the main water su...

Page 5: ...l 16 and the negative to terminal 17 SUPPLY AIR RESET BY SPACE TEMPERATURE Use a 10K type II thermistor sensor installed at the entering water temperature sensor location on PCB2 and configure the uni...

Page 6: ...e for remote annunciation connect wiring to terminal block J10 terminal 18 normally open terminal 17 common and or terminal 16 normally closed J4 9 10 RED BLK RED RED BLK BLK BLK RED BLK RED SENSOR 1...

Page 7: ...t digital input such as duct high limit switch When the jumper is in the top position the input is configured for a voltage input for example a humidity sensor The bottom jumper position is used for m...

Page 8: ...50 60 Hz 20VA 0 83A Use Copper Conductors Only 232 EIA EIA 485 Port 1 Port 2a Therm Dry Unused 5 6 7 8 Network Switches 0 off 1 on MSTP m MSTP s PTP SLTA PlugIn Ethernet 8 7 6 5 Protocol 0 0 0 0 0 0...

Page 9: ...If the standby screen is visible press any key to switch to the HOME menu 2 If another screen is displayed press the HOME to switch to the HOME menu 3 Press the LOGOUT softkey to force the system to...

Page 10: ...ompressor start stop test This is the same test point used to test the VFD bypass Since constant volume units do not have remote VAV termi nals there is no built in delay to allow remote boxes to open...

Page 11: ...es Local schedules are one method of starting and stopping the unit at specified intervals There are four normal schedules that provide day to day opera tion There are twelve holiday schedules that ar...

Page 12: ...ule When an override schedule is active it overrides any nor mal or holiday schedule and forces the unit to occupied mode In the example listed under the holiday schedule assume an override schedule...

Page 13: ...runtime limits or clear the accumulated run times To view run times press the CONFIG softkey on the HOME menu then select the RUNTIME option from the CONFIGURATION menu Use the arrow keys to scroll th...

Page 14: ...entry press EXIT and re start the procedure at Step 6 9905 Motor Nom Volt should equal unit voltage 230V or 460V 9906 Motor Nom Current equal to motor FLA see motor nameplate 9907 Motor Nom Freq alwa...

Page 15: ...elp screens START UP WITH ASSISTANT To start up the VFD with the Start Up Assistant perform the following proce dure 1 Select MENU SOFT KEY 2 The Main menu will be displayed 2 Use the UP or DOWN keys...

Page 16: ...and then press EXIT SOFT KEY 1 to return to main menu NOTE The current parameter value appears above the highlight parameter To view the default parameter value press the UP and DOWN keys simultaneous...

Page 17: ...not be changed 6 Press EXIT SOFT KEY 1 twice to return to the main menu START UP General Complete the start up checklist on page CL 1 before attempting system start up Confirm that compressor suction...

Page 18: ...of these sensors in the custom configuration The following sensors when valid are used for the space tempera ture sensor with the highest precedence at the top of the list Space temperature sensor SPT...

Page 19: ...e 65 F HEAD PRESSURE CONTROL HPC In installations where entering water temperature can fall below 55 F where a water economizer described above is not installed the HPC provides an electronic water fl...

Page 20: ...of each compressor and is set to open at pressures above 570 psig It is wired in the 24 vac control power line of the compressor contactor in series with the LPS and FRZ and disables compressor operat...

Page 21: ...he compres sor and attempt to restart it 15 minutes later assuming there is still a call for cooling On a third failed attempt to run the compressor the compressor will be locked out pending a pow er...

Page 22: ...r control of an air economizer OUTDOOR AIR TEMPERATURE ALARM OAT If an outdoor air temperature sensor is installed and configured an alarm with an ID of oat_alarm will be generated if the temperature...

Page 23: ...ISC1 Disconnect Switch DSP Duct Static Pressure Transducer ECONO Economizer Valve Damper Control EWT Entering Water Temperature Sensor FLTS Filter Status Switch FREEZ Freeze Thermostat Water Economize...

Page 24: ...3 L1 T1 L2 T2 L3 T3 FU10 FU11 FU12 COMP3 151 BLK 157 BLU 154 YEL 150 BLK 156 BLU 153 YEL 149 BLK 155 BLU 152 YEL C3 158 BLK 159 BLK CH3 2 1 3 L2 T2 L3 T3 FU13 FU14 FU15 COMP4 162 BLK 168 BLU 165 YEL 1...

Page 25: ...Z2 409 PNK 408 PNK 407 PNK 406 PNK LPS2 400 BLU 534 BLU HPS1 FRZ1 404 BLU 403 BLU 402 BLU 401 BLU LPS1 TB5 531 BRN 528 BRN 525 BRN 522 BRN 532 BRN 427 BRN 433 BRN 432 BRN 430 BRN 428 BRN 429 BRN 431 B...

Page 26: ...tion PUMP REQUEST FIELD Connection TOWER REQUEST FIELD Connection EXT DEHUMIDIFY Tower Sump Leaving Water 627 ORN 628 BLU 629 BRN FIELD Connection TRMOP FIELD Connection VENTR FIELD Connection TRMCT F...

Page 27: ...701 GRN 630 ORN 631 VIO HRN3 4 3 FIELD Connection Exhaust Fan DSP 640 BLK A B BPS_S 617 BRN 6 5 638 BRN 638 BRN 627 ORN 628 BLU 629 BRN 603 RED 606 BRN 639 RED 607 RED 609 RED 611 RED 613 RED FIELD A...

Page 28: ......

Page 29: ......

Page 30: ...right to discontinue or change at any time specifications or designs without notice and without incurring obligations Catalog No 04 53500117 01 Printed in U S A Form 50XJ 2T Pg 30 8 14 Replaces 50XJ 1...

Page 31: ...INPUT POWER PHASE SEQUENCE BEEN CONFIRMED WITH A METER Y N _______ HAS THE FAN AND MOTOR PULLEY BEEN CHECKED FOR PROPER ALIGNMENT AND DOES THE FAN BELT HAVE PROPER TENSION Y N _______ HAS WATER BEEN P...

Page 32: ..._____________________________________________________________________________________________ _______________________________________________________________________________________________ __________...

Reviews: