Options
Vario II series
76
Operating manual
12.11
9.2 Dispenser
In order to operate the printer in dispensing mode a print order has to
be started and the printer has to be in 'waiting' mode.
Press key
to access the function menu.
In menu 'Print Mode', press key
as long as you arrive at the
'Dispenser' menu.
Press key
to select the menu.
In the first line of the display the dispenser mode can be selected.
In the second line the dispenser offset which is approx. 18 mm can be
set.
Press key
to arrive at the next operating mode.
Off:
It is printed without the labels are dispensed.
I/O static:
The input signal evaluated, i.e. it is printed as long as the signal
exists. The number of labels which was entered at the print start is
printed.
The set dispenser offset is not taken into consideration.
I/O static continuous:
You can find the description of this operating mode in chapter I/O
static.
Continuous means that it is printed as long as new data is transferred
via interface
The set dispenser offset is not taken into consideration.
I/O dynamic:
The external signal is evaluated dynamically, i.e. is the printer in
'waiting' mode a single label is printed at each signal changing. After
the print the set dispenser offset is executed, i.e. a backfeed is
effected.
I/O dynamic continuous:
You can find the description of this operating mode in chapter I/O
dynamic.
Continuous means that it is printed as long as new data is transferred
via interface.
Photocell:
The printer is controlled via photocell. The printer prints automatically
a label if the user takes away the label at the dispensing ledge. The
print order is finished when the target number of labels is reached.
Photocell continuous:
You can find the description of this operating mode in chapter
photocell.
Continuous means that it is printed as long as new data is transferred
via interface.
Press key
res.
to return to the main menu.
Operating modes