Vario II series
Function menu
12.11
Operating manual
67
8.12 Password protection
Press key
to access the function menu.
Press key
as long as you arrive at the 'Password Protection'
menu.
Press key
to select the menu.
Password:
By a password several functions can be blocked, so the user cannot
work with them. There are several applications in which the use of
password protection makes sense (see chapter 12.2 Password, on
page 108).
8.13 Service functions
So that the distributor res. the printer manufacturer at the case
of service can offer fast support, the printer is equipped with
the Service functions menu.
Necessary information such as set parameter can read
directly at the printer (see chapter 8.15 on page 71).
Press key
to access the function menu.
Press key
as long as you arrive at the 'Service Functions' menu.
Press key
to select the menu.
Label parameters:
Indication of label parameters in Volt.
A:
Indication of minimum value.
B:
Indication of difference between minimum and maximum value.
C:
Indication of trigger level. The value is ascertained while measuring
and can be changed.
Press key
to arrive at the next menu item.
Photocell paramters:
DLS:
Indication of transmission photocell level in Volt.
RLS:
Indication of reflexion photocell level in Volt.
OLS:
Indication of ribbon savings photocell level in Volt.
TR:
Indication of transfer ribbon photocell status (either 0 or 1).
H:
Indication of printhead position.
0 = printhead down; 1 = printhead up
Press key
to arrive at the next menu item.
Heater resistance:
To achieve a high print quality, the indicated Ohm value must be set
after an exchange of printhead.