41
ENG
Heos
+0300078EN - rel. 1.6 - 23.11.2017
Mask index Par.
Description
Default
UOM
Min
Max
Possible value descr.
R/W
Bad03
/EC
Select light output position
7
--
0
8
0: --
1: DO1, ..., 8: DO8
9: Y1
10: Y2
11: Y3
R/W
Light output status
0
--
0
1
0: OPEN
1: CLOSED
R
Select light output logic
0
--
0
1
0: N.A; 1: N.C.
R/W
Light output function
0
--
0
1
0: NOT ACTIVE
1: ACTIVE
W
Bad04
/Ed
Select defrost output position
8
--
0
8
0: --
1: DO1, ..., 8: DO8
9: Y1
10: Y2
11: Y3
R/W
Defrost output status
0
--
0
1
0: OPEN
1: CLOSED
R
Select defrost output logic
0
--
0
1
0: N.A; 1: N.C.
R/W
Defrost output function
0
--
0
1
0: NOT ACTIVE
1: ACTIVE
W
Bad05
/EE
Select alarm output position
1
--
0
8
0: --
1: DO1, ..., 8: DO8
9: Y1
10: Y2
11: Y3
R/W
Alarm output status
0
--
0
1
0: OPEN
1: CLOSED
R
Select alarm output logic
0
--
0
1
0: N.A; 1: N.C.
R/W
Alarm output function
0
--
0
1
0: NOT ACTIVE
1: ACTIVE
W
Bad06
/EF
Select auxiliary output position
0
--
0
8
0: --
1: DO1, ..., 8: DO8
9: Y1
10: Y2
11: Y3
R/W
Auxiliary output status
0
--
0
1
0: OPEN
1: CLOSED
R
Select auxiliary output logic
0
--
0
1
0: N.A; 1: N.C.
R/W
Auxiliary output function
0
--
0
1
0: NOT ACTIVE
1: ACTIVE
W
Bad07
/EG
Select anti-sweat heater output position
0
--
0
3
0: --
1: --
2: DO2
3: DO3
R/W
Anti-sweat heater output status
0
--
0
1
0: OPEN
1: CLOSED
R
Select anti-sweat heater output logic
0
--
0
1
0: N.A; 1: N.C.
R/W
Anti-sweat heater output function
0
--
0
1
0: NOT ACTIVE
1: ACTIVE
W
Bad08
/EM
Select liquid injection solenoid output position
0
--
0
8
0: --
1: DO1, ..., 8: DO8
9: Y1
10: Y2
11: Y3
R/W
Liquid injection solenoid output status
0
--
0
1
0: CLOSED
1: OPEN
R
Select liquid injection solenoid output logic
0
--
0
1
0: N.A; 1: N.C.
R/W
Liquid injection solenoid output function
0
--
0
1
0: NOT ACTIVE
1: ACTIVE
W
Bad09
/EN
Select curtain contact output position
0
--
0
8
0: --
1: DO1, ..., 8: DO8
9: Y1
10: Y2
11: Y3
R/W
Curtain contact output status
0
--
0
1
0: CLOSED
1: OPEN
R
Select curtain contact output logic
0
--
0
1
0: N.A; 1: N.C.
R/W
Curtain contact output function
0
--
0
1
0: NOT ACTIVE
1: ACTIVE
W
Bad10
/Eo
Select position of ON/OFF compressor output
0
--
0
8
0: --
1: DO1, ..., 8: DO8
9: Y1
10: Y2
11: Y3
R/W
Status of ON/OFF compressor output
0
--
0
1
0: CLOSED
1: OPEN
R
Select logic of ON/OFF compressor output
0
--
0
1
0: N.A; 1: N.C.
R/W
ON/OFF compressor output function
0
--
0
1
0: NOT ACTIVE
1: ACTIVE
W
Bad13
/Er
Select inverter valve output position
0
--
0
8
0: --
1: DO1, ..., 8: DO8
9: Y1
10: Y2
11: Y3
R/W
Inverter valve output status
0
--
0
1
0: OPEN
1: CLOSED
R
Select inverter valve output logic
0
--
0
1
0: N.O. 1: N.C.
R/W
Inverter valve output function output
0
--
0
1
0: NOT ACTIVE
1: ACTIVE
W
Bad14
/ES
Select condenser fan output position
0
--
0
8
0: --
1: DO1, ..., 8: DO8
9: Y1
10: Y2
11: Y3
R/W
Condenser fan output status
0
--
0
1
0: OPEN
1: CLOSED
R
Select condenser fan output logic
0
--
0
1
0: N.O. 1: N.C.
R/W
Condenser fan output function
0
--
0
1
0: NOT ACTIVE
1: ACTIVE
W