9
• These instructions are aimed at professionally qualified ‘
INSTALLERS OF
ELECTRICAL EQUIPMENT
’ and must respect the local standards and
regulations in force.
All materials used must be approved and must suit the environment in
which the installation is situated and all maintenance operations must be
carried out by professionally qualified technicians.
• This appliance must be used exclusively for the purpose for which it has
been made. ‘
i.e. for the automation of hinged gates
’ with one or two
gate leaves.
- maximum gate length
2 m
(
2,5
m with an electric lock)
- maximum gate weight
200 kg
.
- minimum column width
180 mm
.
CAUTION!
Mechanical stop buffers must be installed in both the
closing and opening positions.
It is the responsibility of the installer to make sure that the following public
safety conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from the main
road to eliminate possible traffic disruptions.
2) The motor must be installed on the inside of the property and not on the public
side of the gate. The gates must not open onto a public area.
3) The gate operator is designed for use on gates through which vehicles are
passing. Pedestrians should use a separate entrance.
4)
The controls must be installed at a height between
1,5
and
1,8 m
and in a
location not accessible to children. Controls installed externally must be
protected by a safety device inhibiting unauthorised use.
5)
At least two warning signs (similar to the example on the
right) should be placed, where they can be easily seen
by the public, in the area of the system of automatic
operation. One inside the property and one on the public
side of the installation. These signs must be indelible and
not hidden by any objects (such as tree branches, decorative fencing etc.).
6) Make sure that the end-user is aware that children and/or pets must not be
allowed to play within the area of a gate installation. If possible include this in
the warning signs.
7) Whenever a fully open gate leaf comes within
at 500 mm
of a fixed structure
the space must be protected by an anticrush buffer.
8) You are advised to protect the system’s lateral access points with pairs of (
FS
)
photocells connected to the stop input, see installation example, component
14 on page 2.
9) If you have any questions about the safety of the gate operating system, do not
install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
BLTOW24M
self-locking
Master
reduction unit with an incorporated encoder,
on-board electronics and an aluminium operator arm.
BLTOW24S
self-locking
Slave
reduction unit with an incorporated encoder
without on-board electronics, complete with aluminium operator arm.
• Direct current drive motor max.
24 Vdc
.
• Permanently lubricated double worm screw reduction unit. Externally
activated manual release system (Cardin patent) managing the release of
the gears form the gate (emergency manoeuvre).
• A plastic framework is fixed to the reduction unit chassis and houses the
electronic programmer, the toroidal transformer and the radio frequency
module. The battery charger and special Cardin emergency
NiMH
batteries
are optional.
• Motor support base in cast aluminium.
Attention!
Only for EU customers -
WEEE marking
.
This symbol indicates that once the products life-span has
expired it must be disposed of separately from other rubbish.
The user is therefore obliged to either take the product to a
suitable differential collection site for electronic and electrical
goods or to send it back to the manufacturer if the intention is
to replace it with a new equivalent version of the same product.
Suitable differential collection, environmental friendly treatment and
disposal contributes to avoiding negative effects on the ambient and
consequently health as well as favouring the recycling of materials.
Illicitly disposing of this product by the owner is punishable by law and
will be dealt with according to the laws and standards of the individual
member nation.
During the opening/closing manoeuvre check for correct operation and
activate the emergency stop button in case of danger. During blackouts the
gate can be released and manually manoeuvred using the supplied release
key (see manual release page 10).
The minimum controls which may be installed are OPEN-STOP-CLOSE,
these controls must be installed in a location not accessible to children and
outside the opening range of the gate.
Before starting the installation of the system check that the structure which
is to be automated is in good working order and respects the local standards
and regulations in force.
To this end make sure that the gate is sufficiently rigid (if necessary reinforce
the structure) and that it pivots easily.
You are advised to grease all the moving parts using lubricants which maintain
unaltered friction characteristics over a period of time and are suitable for
temperatures of
-20 to +70°C
.
• Check the safety measures between the fixed and moving parts:
- a minimum space of
30 mm
must always be left along the entire distance
between the gate and the support column measured throughout the entire
opening angle of the gate.
- make sure that the space between the bottom of the gate and the pavement
never exceeds
30 mm
throughout the entire opening angle of the gate.
• The surface of the gate must not feature openings which allow a person’s
hand or foot to pass through.
• Check the exact positioning of the pivots, and their good working order
(the upper and lower hinges/pivots must be aligned on the same axis).
• Work out the run of the cables according to the command and control
devices fitted and make sure the system conforms to the local standard
and regulations in force (see installation example).
• Check that the appliance is suitable for the size, weight and duty cycle of
the gate to which it is to be applied (see duty cycle on page 20).
ASSEMBLY PROCEDURE
The unit may be positioned either to the
right
or to the
left
of the passageway:
• Move the gate/s to the closed position.
• Choose the value “
A
” according to the required opening angle (fig. 3) and
work out (depending on the structural characteristics of the gate) at what
height the front bracket “
Q
” will be fitted to the gate.
Once the position has been established, fasten the galvanised steel base
“
D
” (fig. 5) using 4 M8 screws and 4 Ø14 steel rawlplugs (not supplied)
making sure that the steel base is perfectly square.
• Fasten the geared motor to the galvanised steel base “
D
” using the screws
“
G
” with relative self-locking nuts and washers.
ATTENTION! IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
USER INSTRUCTIONS
INSTALLATION INSTRUCTIONS
READING THESE INSTRUCTIONS IS IMPORTANT FOR PERSONAL SAFETY. READ THE FOLLOWING REMARKS CAREFULLY BEFORE
PROCEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
IN THIS
ORIGINAL INSTRUCTION MANUAL. NOT READING THESE IMPORTANT INSTRUCTIONS COULD COMPROMISE THE CORRECT WORKING
ORDER OF THE SYSTEM AND CREATE DANGER SITUATIONS FOR THE USERS OF THE SYSTEM. SAVE THESE INSTRUCTIONS FOR FUTURE
USE.
THE ORIGINAL INSTRUCTIONS AND RELATIVE UPDATES ARE AVAILABLE IN DIGITAL FORMAT FROM THE WEBSITE
WWW.CARDIN.IT.
ZVE: 572 - Mod: 04-09-2017
riello elettronica group
®
AUTOMATIC OPENING
APERTURA AUTOMATICA
FERMETURE AUTOMATISÉE
AUTOMATISCHER ÖFFNUNG
Serial number:
Installation company:
Product model:
Installation date:
Weight in kg: