18
TERMINAL BOARD CONNECTIONS
1-2
230 Vac
output for the toroidal transformer
3-4 Programmer power supply
230 Vac
5-6 Programmer earth connection
7-8
BSP
Passive safety input (N.C.) If this contact is open the power supply to
the controls will be interrupted. Insert a normally closed contact which is
able to support a load of
30 Vdc 3A
. This safety device should be installed
in addition to the normal active safety devices (
Caution!
This input cannot
be connected in series with the
FTCI
and
FTCS
as they do not share the
same common). It could also be wired in series to an emergency device in
line with the local standards in force.
9
Controlled output, powering external loads
24 Vdc
(1)
10
CMN
common for all inputs and outputs
11 Output, powering permanent external loads
24 Vdc
(1)
12
LP 24 Vdc 25 W
output for warning lights, intermittent activation (50%),
12,5 W
continuous activation
13
CMN
common for all inputs and outputs
14
LS
indicator light output
24 Vdc,
3 W
15
TAI
(NO contact) internal opening button input
16
CMN
common for all inputs and outputs
17
TAE
(NO contact ) input:
- with enabled traffic light signals: external opening button;
- with disabled traffic light signals: limited opening button
(opens the door for about 2,5 m)
18
TD
(NO contact) sequential command button input
19
CMN
common for all inputs and outputs
20
TC
(NO contact) closing button input
21
TB
(NC contact) stop button input (The opening of this contact interrupts
the cycle until a new movement command is given)
22
CMN
common for all inputs and outputs
23
FTCI
(NC contact) Safety and control devices in input (photocells invert the
travel direction when an obstruction is detected). Opening this contact will
provoke a travel direction inversion during closure due to the cutting in of
the safety device.
24
FTCS
(contact NC) Safety and control devices in input. (stop photoelectric
cells). The opening of this contact will block all movement, until the obstruc-
tion has been removed and the pause time has elapsed, due to the safety
device cutting in, the door will then continue moving in the closing direction
(only with automatic reclosing enabled).
CSP
(contact NC) Safety buffer input (only with dip 7 "
ON
". Opening this
contact will provoke a travel direction inversion of
8 cm
and a pause of
3
minutes
, after which the motor will continue moving in the original direction
after a
10 second
preflashing period has elapsed. If a security device cuts in
during closing at less than
40 cm
, the travel direction inversion will be
40 cm
.
25
CMN
common for all inputs and outputs
26
CSPA
analogical safety edge input
8.2
k
Ω
27
CMN
common for the emergency buttons
28
EMRG 1
(NO contact) emergency manoeuvre input 1
29
EMRG 2
(NO contact) emergency manoeuvre input 2
30
Outer conductor for radio receiver antenna.
31
Inner conductor for radio receiver antenna (if an external antenna
is fitted use a coaxial type cable
RG58
with an impedance of
50
Ω).
32-33
LC
Courtesy light output
24 Vdc 15 W
.
Note
(1)
The total of the 2 external device outputs must not exceed
10W.
ALL UNUSED NC CONTACTS MUST BE BRIDGED
and consequently the
security device test must also be deactivated (
TFTC – DIP 8
). If you want
to activate the
FTCI
test both the transmission and receiver parts of the
photocell must be connected to the binding post marked “
CTRL 24 Vdc
”.
If the test is active there will be a 1 second delay between the command
transmission and movement of the door.
Switch on the power and make sure that the indicator LEDS are in the fol-
lowing condition (if the display is off press the "
PROG
" button to display the
status of the security devices:
- L1
Wrong battery connection
OFF
(2)
- L2
Power on
ON
- L3
Battery charging
OFF
(3)
- L3
Transmitter code programming
OFF
- L5
Blocking button "
TB
"
ON
(4)
- L6
Inverting photoelectric cells "
FTCI
"
ON
(4)
- L7
Stop photoelectric cells "
FTCS
" or the safety edge "
CSP
"
ON
(4)
- L8
Safety edge "
CSPA"
8.2 K
Ω
ON
(4)
- L9 "CSPF"
from the optional "
SCL
" card
ON
(4)
- L10
Internal opening button "
TAI
"
OFF
- L11
Closing button "
TC
"
OFF
- L12
External opening button "
TAE
"
OFF
- L13
Dynamic button "
TD/CH1
"
OFF
Note
(2)
:
If this LED is "
on
" disconnect the battery immediately and contact the
after sales service.
Note
(3)
:
This LED is "
on
" when the battery is under charge.
Note
(4)
:
The leds are lit if the relative safety devices are not activated. Check that
the activation of the safety devices switch the corresponding LEDS off.
If the
power on LED "L2" doesn't light up
check the condition of the fuses and
the power cable connection at binding posts 3,4.
If
one or more of the safety LEDS do not light up
check the contacts of the
relative security devices and check that the unused safety device contacts have
been bridged.
B1
Signal buzzer “
via radio
” mode
CN1
Motor Faston connection
D1
Six-segment LED display
DS1
Selection dip-switch
F1
4A
blade fuse
(5)
(
24V
circuit protection during battery operation)
F2
15A
blade fuse
(5)
(motor protection during battery operation)
F3
4A
blade fuse
(5)
(
24V
transformer power supply protection)
F4
15A
blade fuse
(5)
(motor power protection from transformer)
J3
Encoder connection
J6
Optional command card connection "
SCL
"
J7
Bridge "
UPM ENABLE"
M1
Transmitter code memory module
P1
Programming button (
PROG
)
P2
Transmitter code memorization button (
MEMO
)
P3
Transmitter code cancellation button (
DEL
)
R1
Radio frequency module,
433 MHz
for
S449
transmitters
Note
(5)
:
These are
automotive
type blade fuses (max. voltage
58 V
)
17
Collegamenti scheda base
311/GL124EBSS
26-10-2005
DC0401
Description :
Product Code :
Date :
Drawing number :
P.J.Heath
CARDIN ELETTRONICA S.p.A
- 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
Elettronica per basculante
(con 6 display a led - selezione a dipswitch )
CS 1202.0
1
DC0401
CMN
TD
CMN
TC
LP
TA
I
CMN
11
12
13
14
15
16
17
18
19
20
21
22
P2
P1
B1
J2
J3
1 2 3 4 5 6 7 8 9 10
ON
DS1
EMRG
1
CMN
L5
L4
L3
L2
L8
L7
L9 L11
L6
D1
9
10
30Vd
c
8
7
CTRL 30Vd
c
CMN
FTCI
CSP
A
UP
M
R
.MEM
TFTC
FTCS
FTCI
DI
R
LP
PL
P
RA
TD
32
33
5
6
3
4
27
28
29
LS
TA
E
EMRG
2
P3
MEMO
ENCODER
-
PROG
DEL
L1
L N
1
2
TRANSF
230V
J4
J5
+
R1
M1
CN1
30
31
LC
230 Vac
F1
F2
F3
F4
23
24
25
26
BSP
FTCS
CMN
CMN
TB
J6
L10
L13
L12
J7
UPM ENABL
E