![Car-O-Liner PointX Instruction Manual Download Page 91](http://html.mh-extra.com/html/car-o-liner/pointx/pointx_instruction-manual_2555223091.webp)
45929, EN - rev. 6, 2019-03
90
5.5
The Measuring tab
The measuring methods available in the PointX software are Normal-,
Absolute- and Point-To-Point (P2P) measuring.
5.5.1
The Normal measuring view
Measuring point
information box
displays selected
measuring point,
tube and adapter.
Yellow frame for
Centering, green
frame for Measuring.
Reference point
information box
marked with black
frame. Displays
selected
measuring point,
tube, adapter and
configuration.
Reference point
photo
Measuring point
photo
Target button
Measuring point
values table
Shows measured
value, DataSheet
value and
difference between
the two values.
Reference and
measuring points
Black circle:
Reference point
Yellow circle
:
Centering point
Green circle
:
Measuring point.
Measuring point preview
See previews of measuring points
(without selecting a specific
measuring point) by placing the
marker on a measuring point.
Centering and measuring
workflow information
Normal measuring mode
(default mode)
Shortcut to
“Tolerance
settings”
Click on icon to
zoom explanatory
drawing.