4.1.5
Magnetic attachment
This attachment is used to facilitate the the fixing of the measuring arm to
the reference point, for example when the reference point is out of reach
for your left hand,
see figure 4.1
.
It is
developed to suit most vehicle
models on the market. The length of the magnetic attachment corresponds
to the length of the 100 mm measuring tube fitted with a 25 or 35 mm tip.
Figure 4.4 Magnetic attachment device.
4.1.6
Measuring adapters (sockets and tips)
The PointX measuring adapter system includes various sockets and tips.
The sockets and tips snap into the top of the measuring tubes.
Measurements are printed on each adapter.
For complete chart of measuring adapters,
see chapter 15 Spare parts.
Figure 4.5 Examples of different measuring adapters.