3-3. Adjustment / Settings
(1) Paper feed motor adjustment
1) When attaching the motor, fasten the screws so that the belt is properly stretched (in the direction indicated by the blue arrow in the photo
below).
2) After replacement, be sure to perform the service test print, and confirm that no strange noise or faulty print operation (due to dislocation of
the belt or gear, or out-of-phase motor, etc.) occurs.
(2) Document pressure sheet (sponge sheet) replacement
1) Peel off the cover sheet from the double-sided adhesive tape on the back of the document pressure sheet.
With the long-side down, position the upper-left corner of the document pressure sheet at the scanning reference point on the platen glass
(back left where the red lines cross in the photo above).
2) Slowly close the document pressure plate while maintaining the hinge position. The document pressure sheet will attach to the plate.
3) Open the plate to confirm the following:
- No extension of the sponge edges over the mold part of the upper scanner cover.
- No gap between the platen glass reference edges and the corresponding sponge edges.
- No shades or streaks in monochrome test printing without a document on the platen glass.
MP630 / MP638 --- 3. REPAIR
TABLE OF CONTENTS
The screws securing the paper feed motor may be loosened only at replacement of the paper feed motor unit. DO
NOT loosen them in other cases.
32 / 45