3-2. Special Notes on Repair Servicing
(Click on the image to enlarge it.)
Be sure to protect the machine from static electricity in repair servicing, especially for the LCD, operation panel board, scanner unit, logic
board, card board, IrDA board, and PE sensor board.
(1) External housing, scanner unit, and document cover removal
MP630 / MP638 --- 3. REPAIR
TABLE OF CONTENTS
1) Remove the cassette.
2) Open the front door and scanner unit, then remove the side cover R (2 screws).
<The scanner unit hinges are fitted in the right and left side covers.>