Chapter 6
6-10
4
VHT12
OUT
Head Transistor drive Power supply
5
H1-F-DATA-10-EV
OUT
Even head data signal 10(F)
6
IO_ASIC_SDA
IN/OUT
EEPROMcontrol signal (data)
7
IO_ASIC_SCL
OUT
EEPROMcontrol signal (clock)
8
H3V_1
OUT
Power supply (+3V)
9
H1-C-DIA1
IN
Head DI sensor signal 1(C)
10
/H1-A-HE-1
OUT
Head heat enable signal 8(E)
11
VH1
OUT
Power supply
12
VH1
OUT
Power supply
13
VH1
OUT
Power supply
14
VH2
OUT
Power supply
15
VH2
OUT
Power supply
16
H1-E-DATA-9-OD
OUT
Odd head data signal 9(E)
17
/H1-F-HE-11
OUT
Head heat enable signal 11(F)
18
H1-E-DIA1
IN
Head DI sensor signal 1(E)
19
H1-D-DIA1
IN
Head DI sensor signal 1(D)
20
H3V_1
OUT
Power supply
21
H3V_1
OUT
Power supply
22
H1-B-DATA-3-EV
OUT
Even head data signal 3(B)
23
H1-A-DATA-0-EV
OUT
Even head data signal 0(A)
24
/H1-B-HE-2
OUT
Head heat enable signal 2(B)
25
VH1
OUT
Power supply
26
VH1
OUT
Power supply
27
H1-D-DIA2
IN
Head DI sensor signal 2(D)
28
/H1-E-HE-8
OUT
Head heat enable signal 8(E)
29
H1-E-DIA2
IN
Head DI sensor signal 2(E)
30
H1-F-DIA2
IN
Head DI sensor signal 2(F)
31
/H1-E-HE-9
OUT
Head heat enable signal 9(E)
32
H1-D-DATA-7-EV
OUT
Even head data signal 7(D)
33
/H1-D-HE-6
OUT
Head heat enable signal 6(D)
34
H1-C-DATA-5-OD
OUT
Odd head data signal 5(C)
35
H1-C-DATA-4-EV
OUT
Even head data signal 4(C)
36
H1-A-DATA-1-EV
OUT
Even head data signal 1(A)
37
H1-A-DIA2
IN
Head DI sensor signal 2(A)
38
H1-B-DIA2
IN
Head DI sensor signal 2(B)
39
/H1-C-HE-4
OUT
Head heat enable signal 4(C)
40
H1-D-DATA-7-OD
OUT
Odd head data signal 7(D)
41
H1-E-DATA-8-OD
OUT
Odd head data signal 8(E)
42
/H1-F-HE-10
OUT
Head heat enable signal 10(F)
43
H1-F-DATA-11-EV
OUT
Even head data signal 11(F)
44
H1-E-DATA-8-EV
OUT
Even head data signal 8(F)
45
H1-D-DATA-6-EV
OUT
Even head data signal 6(D)
46
H1-C-DIA2
IN
Head DI sensor signal 2(C)
47
H1-C-DATA-5-EV
OUT
Even head data signal 5(C)
48
H1-B-DIA1
IN
Head DI sensor signal 1(B)
49
/H1-A-HE-0
OUT
Head heat enable signal 0(A)
50
H1-B-DATA-2-OD
OUT
Odd head data signal 2(B)
51
H1-B-DATA-3-OD
OUT
Odd head data signal 3(B)
52
H1-C-DATA-4-OD
OUT
Odd head data signal 4(C)
53
GND
-
GND
54
GND
-
GND
55
GND
-
GND
56
H1-F-DATA-11-OD
OUT
Odd head data signal 11(F)
57
H1-E-DATA-9-EV
OUT
Even head data signal 9(E)
58
GND
-
GND
59
H1-D-DATA-6-OD
OUT
Odd head data signal 6(D)
60
/H1-C-HE-5
OUT
Head heat enable signal 5(C)
61
/H1-B-HE-3
OUT
Head heat enable signal 3(B)
62
H1-A-DIA1
IN
Head DI sensor signal 1(A)
63
H1-A-DATA-1-OD
OUT
Odd head data signal 1(A)
64
GND
-
GND
65
GND
-
GND
66
GND
-
GND
67
GND
-
GND
68
H1-F-DATA-10-OD
OUT
Odd head data signal 10(F)
J103 (Printhead)
Pin Number
Signal name
IN/OUT
Function
Summary of Contents for iPF750 series
Page 1: ...Jul 25 2012 Service Manual iPF760 750 series ...
Page 2: ......
Page 6: ......
Page 11: ...Chapter 1 PRODUCT DESCRIPTION ...
Page 12: ......
Page 14: ...Contents 1 7 3 5 Self diagnostic Feature 1 71 1 7 3 6 Disposing of the Lithium Battery 1 72 ...
Page 87: ...Chapter 2 TECHNICAL REFERENCE ...
Page 88: ......
Page 99: ...Chapter 2 2 9 ...
Page 145: ...Chapter 3 INSTALLATION ...
Page 146: ......
Page 148: ......
Page 152: ......
Page 153: ...Chapter 4 DISASSEMBLY REASSEMBLY ...
Page 154: ......
Page 156: ......
Page 214: ...Chapter 4 4 58 2 Shaft Cleaner 1 F 4 119 1 ...
Page 215: ...Chapter 4 4 59 3 Upper Cover Hinge Catch 1 Roll Cover Slide Guide 2 F 4 120 2 1 ...
Page 218: ......
Page 219: ...Chapter 5 MAINTENANCE ...
Page 220: ......
Page 222: ......
Page 227: ...Chapter 5 5 5 ...
Page 228: ......
Page 229: ...Chapter 6 TROUBLESHOOTING ...
Page 230: ......
Page 232: ......
Page 250: ......
Page 251: ...Chapter 7 SERVICE MODE ...
Page 252: ......
Page 254: ......
Page 305: ......
Page 306: ......
Page 307: ...Chapter 8 ERROR CODE ...
Page 308: ......
Page 310: ......
Page 327: ...Jul 25 2012 ...
Page 328: ......