4
4
4-25
4-25
Parts Replacement and Cleaning Procedure > Removing the Motors > Removing the Entrance Roller Release /Stopper HP Motor
Parts Replacement and Cleaning Procedure > Removing the Motors > Removing the Entrance Roller Release /Stopper HP Motor
Removing the Entrance Roller Release /Stopper HP Motor
1) Remove the harness from the harness guide.
2) Disconnect one relay connector.
3) Remove one screw and then the cover.
x1
F-4-70
F-4-70
4) Remove two reuse bands.
5) Remove two screws and then the cover.
x2
x2
F-4-71
F-4-71
6) Remove three resin rings, two pulleys, one gear, one belt, and three parallel pins.
F-4-72
F-4-72
7) Remove two screws and then the entrance roller release /stopper HP motor along with the
mount.
8) Remove two screws and then the entrance roller release /stopper HP motor.
x4
F-4-73
F-4-73