64
OSD Menu
Item
Setting Options (underline indicates factory default)
Vector Scope
Configures various settings for the vector scope. Vector scope displays the intensity of color signals
and hue with the horizontal axis showing the color difference signal Cb and the vertical line showing
Cr.
Red
Green
Yellow
Blue
Cyan
Magenta
(Cb, Cr) = (255, 255)
(Cb, Cr) = (0, 0)
Cr
Cb
Note
• Vector scope cannot be displayed in the following cases:
-
When an enlarged image is displayed
-
When "Frame Hold" (during interlace signal or PsF signal) or "False Color" is "On"
-
When "Peaking 1" or "Peaking 2" is selected
-
During execution of "Playback File" under "Screen Capture"
-
While "Test Pattern" is displayed
• Only the signal set by "Marker/TC/WFM/VEC Input" is displayed in the "Multi View (Quad)" or
"Multi View (Dual)" display.
• When "Vector Scope" is set to "On", "Wave Form Monitor" turns "Off".
Enable
Switches the vector scope On, Off.
On, Off
Target
Sets the target.
75%, 100%
Position
Selects the display position.
Bottom Left, Bottom Right
Note
• This setting becomes invalid in the "Multi View (Dual)" display.