![Canature 105STS 90 -1.5](http://html1.mh-extra.com/html/canature/105sts-90-1-5/105sts-90-1-5_installation-operation-and-service-instructions_3864878038.webp)
Operation Section 7
Page 7 —6
105 Softener
Brine Draw / Slow Rinse Position Section 7.5
The brine draw / slow rinse is actually two cycles that occur even though the control
valve piston does not move during this time. The brine valve is open during these cycles.
The first part of the cycle is the brine draw. Water from the valve flows through the
through the injector, (or aspirator), assembly. This water flow creates a vacuum which
results in drawing in a brine solution from the brine tank. This mixed water / brine solution
then flows through the media bed and out to drain.
For a “down flow” unit, the brine enters from the top of the unit, DOWN through the
media bed, into the hub and laterals, up the riser tube & out to drain. This is position #9 on
the dial.
Summary of Contents for 105STS 90 -1.5"
Page 1: ...105 Valve Installation Operation Service Instructions 105 Series STS Softener 80150418 1 31 19...
Page 2: ...105 Valve This page intentionally left blank...
Page 11: ...SPECIFICATIONS SECTION 2 Page 2 6 105 STS Softener 105 Valve Dimensions Section 2 5...
Page 35: ...Operation Section 7 Page 7 3 105 Softener Service Position...
Page 37: ...Operation Section 7 Page 7 5 105 Softener Backwash Position...
Page 39: ...Operation Section 7 Page 7 7 105 Softener Brine Draw Slow Rinse Position...
Page 42: ...Operation Section 7 Page 7 10 105 Softener Rinse Position...
Page 51: ...Programming Section 8 Page 8 8 Main Menu Setup And Programming Section 8 4 105 STS Control...
Page 52: ...Programming Section 8 Page 8 9 Main Menu Setup And Programming Section 8 4 105 STS Control...
Page 53: ...Programming Section 8 Page 8 10 Main Menu Setup And Programming Section 8 4 105 STS Control...
Page 54: ...Programming Section 8 Page 8 11 Main Menu Setup And Programming Section 8 4 105 STS Control...
Page 90: ...TROUBLE SHOOTING Section 11 Page 11 1 105 Valve Troubleshooting Section 11...
Page 91: ...TROUBLE SHOOTING Section 11 Page 11 2 105 STS Softener Valve Troubleshooting Section 11...