![Canature 105STS 90 -1.5](http://html1.mh-extra.com/html/canature/105sts-90-1-5/105sts-90-1-5_installation-operation-and-service-instructions_3864878036.webp)
Operation Section 7
Page 7 —4
105 Softener
Regeneration Section 7.3
The regeneration procedure is performed automatically by the softener after the cycle
controller is started. Each regeneration cycle consists of four steps. For down flow
regeneration the cycles are #1 backwash, #2 brine draw / slow rinse, #3 fast rinse, and #4
brine tank refill.
Backwash Position Section 7.
During backwash, water is directed down the riser tube, out the bottom hub and
laterals, then upwards through the softener resin and out to drain. This expands the media
bed, releasing any trapped particles, and cleans it thoroughly. The standard backwash
cycle is usually been factory pre-set to take place for 9 or 10 minutes. This is position #7 on
the dial.
Summary of Contents for 105STS 90 -1.5"
Page 1: ...105 Valve Installation Operation Service Instructions 105 Series STS Softener 80150418 1 31 19...
Page 2: ...105 Valve This page intentionally left blank...
Page 11: ...SPECIFICATIONS SECTION 2 Page 2 6 105 STS Softener 105 Valve Dimensions Section 2 5...
Page 35: ...Operation Section 7 Page 7 3 105 Softener Service Position...
Page 37: ...Operation Section 7 Page 7 5 105 Softener Backwash Position...
Page 39: ...Operation Section 7 Page 7 7 105 Softener Brine Draw Slow Rinse Position...
Page 42: ...Operation Section 7 Page 7 10 105 Softener Rinse Position...
Page 51: ...Programming Section 8 Page 8 8 Main Menu Setup And Programming Section 8 4 105 STS Control...
Page 52: ...Programming Section 8 Page 8 9 Main Menu Setup And Programming Section 8 4 105 STS Control...
Page 53: ...Programming Section 8 Page 8 10 Main Menu Setup And Programming Section 8 4 105 STS Control...
Page 54: ...Programming Section 8 Page 8 11 Main Menu Setup And Programming Section 8 4 105 STS Control...
Page 90: ...TROUBLE SHOOTING Section 11 Page 11 1 105 Valve Troubleshooting Section 11...
Page 91: ...TROUBLE SHOOTING Section 11 Page 11 2 105 STS Softener Valve Troubleshooting Section 11...