PLANNING SYSTEM LOCATION SECTION 3
Page 3- 2
Planning Location For Installation.
Section 3.2
MATERIALS YOU MAY NEED
- Use the drawings in section 3.3 as a guide for the materials required for the installation. The
drawings show typical piping diagrams. All interconnecting piping, isolation & bypass valves,
sample points / pressure gauges, etc. are not supplied with the unit.
- If the interconnecting piping is rigid, flex connectors will be required on all connections to
the media tank as some movement is required. A flex connection may also be required on the
drain line as well if the piping is rigid. The standard systems do not include flex connectors
but can be supplied as optional items with the system.
- A vacuum breaker is recommended on the inlet of each media tank. The standard systems
do not include vacuum breakers but can be supplied as optional items with the system.
-Note: Due to slight expansion and contraction of the media tanks, the piping must be
designed to all some movement as well as protection from vacuum, flex connectors and a
vacuum breakers may be required. Failure to install or improperly install them will void the
warranty. See drawing below.
- To assist in servicing the control valve, place unions or flanges on the piping connections to
the control valve.
- Install unit isolation and system bypass valves. These valves allow you to turn off water to
individual units in the system, for servicing. The full-line bypass will allow water to service if
the system is taken offline for service.
- Inlet and outlet sample points and pressure gauges are required to confirm proper operation
of the system.
- Minimum inside diameter hose or
pipe is required for the conditioner
valve drain (see section 4). The drain
connection at the valve is 1.5” or 2”
male pipe thread. Also, on softeners,
a length of 5/8” hose is needed for
the drain overflow on brine tanks.
105 Softener
Summary of Contents for 105STS 90 -1.5"
Page 1: ...105 Valve Installation Operation Service Instructions 105 Series STS Softener 80150418 1 31 19...
Page 2: ...105 Valve This page intentionally left blank...
Page 11: ...SPECIFICATIONS SECTION 2 Page 2 6 105 STS Softener 105 Valve Dimensions Section 2 5...
Page 35: ...Operation Section 7 Page 7 3 105 Softener Service Position...
Page 37: ...Operation Section 7 Page 7 5 105 Softener Backwash Position...
Page 39: ...Operation Section 7 Page 7 7 105 Softener Brine Draw Slow Rinse Position...
Page 42: ...Operation Section 7 Page 7 10 105 Softener Rinse Position...
Page 51: ...Programming Section 8 Page 8 8 Main Menu Setup And Programming Section 8 4 105 STS Control...
Page 52: ...Programming Section 8 Page 8 9 Main Menu Setup And Programming Section 8 4 105 STS Control...
Page 53: ...Programming Section 8 Page 8 10 Main Menu Setup And Programming Section 8 4 105 STS Control...
Page 54: ...Programming Section 8 Page 8 11 Main Menu Setup And Programming Section 8 4 105 STS Control...
Page 90: ...TROUBLE SHOOTING Section 11 Page 11 1 105 Valve Troubleshooting Section 11...
Page 91: ...TROUBLE SHOOTING Section 11 Page 11 2 105 STS Softener Valve Troubleshooting Section 11...