START-UP INSTRUCTIONS
(CONTINUED)
SYSTEM DIAGRAM
1.
Plug the valve and main controller into an approved power source.
2.
Connect data(4 pin) and power(2 pin) cables between multiple valves via daisy chain from the main controller. Also ensure all meter cables are
plugged in.
3.
Step each valve into the BACKWASH position. For the MTS valve, this must be done on the MAIN controller. Use the UP or Down key to highlight
each tank in the system. Press and hold the SET / REGEN button for 3 seconds to start a manual regeneration for that tank.
4.
Open the outlet isolation valve on each tank slowly and allow water to enter the unit. Allow all air to escape from the unit before turning the
water on fully then allow water to run to drain for 3-4 minutes or until all media fines are washed out of the tank indicated by clear water in the
drain hose.
5.
For softener systems, press any button on each slave valve to advance to the BRINE position. Check the water level in the brine tank to ensure
the valve is drawing brine properly.
6.
Press any button on each slave valve to advance to the RINSE position. Check the drain line flow. Allow the water to run for 3-4 minutes or until
the water is clear.
7.
For softener systems, press any button on each slave valve to advance to the REFILL position. Check that the valve is filling water into the brine
tank. Allow the valve to refill for the full amount of time as displayed on the screen to insure a proper brine solution for the next regeneration.
8.
The valve will automatically advance to the SERVICE position when the refill cycle is complete.
9.
Open the inlet and outlet isolation valves. Close the main bypass valve.
10.
Add salt into the brine tanks.
11.
Program the system.