4
5
MENU SET & REGEN
INSTALLATION INSTRUCTIONS
START-UP INSTRUCTIONS
1.
Locate the system close to a drain where the system will be installed. The surface should be clean and level.
2.
Connect the inlet and outlet of the softener using appropriate fittings. Perform all plumbing according to local plumbing codes.
Any solder joints near the valve or any other plastic connections must be done before connecting any piping. Always leave at least 6” (152 mm)
between the joints when soldering pipes that are connected. Failure to do this could cause damage.
3.
Connect 3/4” drain hose to each valve and secure it with a hose clamp. Run the drainhose to the nearest drain pipe. This can be ran up overhead
or down along the floor. If running the drain line more than 20 ft overhead, it is recommended to increase the hosesize to 1”.
NEVER MAKE A DIRECT CONNECTION INTO A WASTE DRAIN. A PHYSICAL AIR GAP OF AT LEAST 1.5” SHOULD BE USED TO AVOID
BACTERIA AND WASTEWATER TRAVELLING BACK THROUGH THE DRAIN LINE INTO THE SYSTEM
.
4.
Connect the brine tanks to each valve.
5.
Close the isolation ball valves to each control valve. Open the main bypass ball valve to the open position. Slowly turn on the main water
supply. At the nearest cold treated water tap nearby open and let water run a few minutes or until the system is free of any air or foreign
material resulting from the plumbing work.
6.
Make sure there are no leaks in the plumbing system before proceeding. Close the water tap when water runs clean.
7.
Open the brine tank salt lid and add water until there is approximately 3” (75 mm) of water in the tank. Do not add salt to the brine tank
at this time
8.
Proceed to start up instructions.
NOTE: The unit is not ready for service until you complete the start-up instructions.
MENU -
Enter or exit the system menu. Press and hold the
button for 3 seconds to unlock the screen.
SET/REGEN -
Press this button to select a program or to save the
settings. Press and hold the button for 3 seconds to
initate a manual regeneration.
DOWN / UP -
Press these buttons to increase or decrease the value of
the settings. Press the buttons to enter the previous or
the next menu.
KEY PAD CONFIGURATION