background image

Table of Contents

INTRODUCTION  

4

SYSTEM CONFIGURATION  

INSTALLATION INSTRUCTIONS  

5

 START-UP INSTRUCTIONS  

5

SYSTEM DIAGRAM  

6

PROGRAMMING  

7

ADVANCED PROGRAMMING  

17

MTS WIRING SCHEMATICS 

20

REMOVING POWER HEAD ASSEMBLY  

24

REPLACE DRAIN LINE FLOW CONTROL (DLFC)  

25

REPLACE BRINE LINE FLOW CONTROL (BLFC)  

25

REPLACING OR CLEANING INJECTORS  

26

MTS SYSTEM COMPONENTS 

27

POWER HEAD EXPLODED VIEW 

28

POWER HEAD PARTS NUMBERS 

29

VALVE BODY EXPLODED VIEW 

30

VALVE BODY PARTS NUMBERS 

31

TROUBLE SHOOTING 

33

MAINTENANCE LOGS 

34

WARRANTY 

40

Summary of Contents for 95MTS

Page 1: ...nual 95MTS Multi Tank Systems Water Softener Canature WaterGroup Canada Inc 855 Park St Unit 1 Regina SK S4N 6M1 Toll Free 877 288 9888 Canature WaterGroup U S A Inc 6353 Commerce Drive Whitestown IN...

Page 2: ......

Page 3: ...MTS WIRING SCHEMATICS 20 REMOVING POWER HEAD ASSEMBLY 24 REPLACE DRAIN LINE FLOW CONTROL DLFC 25 REPLACE BRINE LINE FLOW CONTROL BLFC 25 REPLACING OR CLEANING INJECTORS 26 MTS SYSTEM COMPONENTS 27 PO...

Page 4: ...s below the point where channeling can occur the system will also recycle product water to maintain high quality BATTERY BACK UP A battery back up system allows the controller to continue metering and...

Page 5: ...IN LINE INTOTHE SYSTEM 4 Connect the brine tanks to each valve 5 Close the isolation ball valves to each control valve Open the main bypass ball valve to the open position Slowly turn on the main wate...

Page 6: ...ds to start a manual regeneration for that tank 4 Open the outlet isolation valve on each tank slowly and allow water to enter the unit Allow all air to escape from the unit before turning the wateron...

Page 7: ...ton to enter the menu icon you want to edit The displayed value will begin flashing Press the UP DOWN button to adjust the value Press the SET button again to accept the change The first three menus a...

Page 8: ...eset regeneration time a regeneration will occur The regeneration can be sched uled on certain days of the week or by set intervals of days between The outlet valve will close to prevent any raw water...

Page 9: ...he System Setting page and return to the Main Menu If you are changing a Main PCB or Slave PCB it may be necessary to format them Format SlaveValve Restore History Data and Restore Settings are covere...

Page 10: ...Peak Period Block Out Auxillary Outputs PROGRAMMING CONTINUED Press the UP DOWN button to highlight the desired menu con Press the SET button to enter the FeedWater menu In the FeedWater menu you can...

Page 11: ...e on line TRIP FLOW RATE OFF This value controls the flow rate limit that the actual flow must be less than before the tank will come off line The default delay time is 5 minutes and is not adjustable...

Page 12: ...the Auxiliary Outputs menu For detailed program ming instructions please see the Advanced Programming section Press the UP DOWN button to highlight the desired menu icon Press the SET button to enter...

Page 13: ...of water passed through the system Press the UP DOWN button to highlight the desired menu icon Press the SET button to enter the ProductWater Polish menu The Min Flow Rate setting will control at wha...

Page 14: ...OCK FILTER METER DELAY FILTER METER IMMEDIATE FILTER PRESSURE DROP System Type SOFTENER DEMAND FLOW FILTER TIME CLOCK FILTER METER DELAY FILTER METER IMMEDIATE FILTER PRESSURE DROP System Type SOFTENE...

Page 15: ...on will occur Press the UP DOWN button to highlight the desired menu icon Press the SET button to enter the System Size menu In the System Size menu you can adjust the number of tanks valves in the sy...

Page 16: ...ackwash and Rinse times The times apply to all the tanks in the system Press the UP DOWN button to highlight the desired menu icon Press the SET button to enter the Advanced Settings menu Press the UP...

Page 17: ...s such as a pressure switch that could signal a regeneration RS OFF is the default value RS ON Immediately would signal a regeneration as soon as the remote button or switch is pushed RS ON Delay woul...

Page 18: ...sword Salt Efficiency Salt Efficiency Settings High Efficiency 6 Lbs CF 2000 Grains Standard Efficiency 10 Lbs CF 4000 Grains High Capacity 15 Lbs CF 5000 Grains Minimum Residual 15 3 Minimum Residual...

Page 19: ...A System Setting page will be displayed Press the MENU button to exit the System Setting page and return to the Main Menu If you wish to erase the current valve history Diagnostic Information it will...

Page 20: ...20 Power Adaptor Outlet AC 24V 2500mA Power Adaptor Outlet AC 24V 2500mA MTS WIRING SCHEMATICS SOFTENER OR FILTER WIRING DIAGRAM...

Page 21: ...24V 2500 MA 11040051 Valve Motor 24V AC Communication Cable 11200007681 3G Battery DC 6V Computer PLUG PC3 Front View 050420031 PLUG PC3 Back View 050420031 AUX Power In UNIT 2 UNIT X MAX 16 Valve Bod...

Page 22: ...Valve Solenoid Valve DC 24V Polish Valve Solenoid Valve DC 24V Valve Motor 24V AC Communication Cable 11200007681 3G Battery DC 6V Computer UNIT 2 UNIT X MAX 16 Communication Cable 11200076 PLUG PC3...

Page 23: ...et Valve Electric Ball Valve 24V DC Power Adaptor Outlet AC 24V 2500 MA 11040051 Valve Motor 24V AC Communication Cable 11200007681 3G Battery DC 6V Computer UNIT 2 UNIT X MAX 16 Communication Cable 1...

Page 24: ...key insert Cam Hole turn the Cam anti clockwise to the backwash position Remove the Connector Remove the Locking Bar Pull the Power Head Assembly outwards Automatically remove the Power Head Assembly...

Page 25: ...OL BLFC To replace the Drain Line Flow Control DLFC Remove the Drain Line Clip Pull the Drain Line Elbow Assembly outward Pull the DLFC Holder outward from the Drain Elbow Replace the DLFC To replace...

Page 26: ...Injector Cover assembly outward Slightly pull out the Screen Replace the Injector Nozzle Slightly pull out the Air Disperser Replace the InjectorThroat Reassemble using the reverse procedure Sediment...

Page 27: ...BNT950 MTS SLAVE 4 C W 1 25 BALLVALVE 10010056 1 MTS MAIN CONTROLLER 60010182 MTS COMMUNICATION CABLE 2M 60010197 MTS COMMUNICATION CABLE 6M 60010083 MTS POWERTRANSFORMER 60010083 120V INPUT 24V OUTPU...

Page 28: ...28 A22 A20 A21 A18 A19 A13 A14 A15 A16 A17 A12 A11 A28 A30 A31 A10 A7 A8 A9 A3 A6 A2 A4 A5 A1 A32 A38 A32 A33 A34 A35 A36 A37 A23 A24 A25 A26 A27 A39 A40 A41 A29 POWER HEAD EXPLODED VIEW...

Page 29: ...ring 8 2 4 A22 05040038 95 95MTS Cable Jaket 2 A23 60095611 Meter Cable 1 A24 26010028 O Ring 28x2 65 1 A25 60095031 BrineValve Connector 1 A26 60095606 O ring 4 1 5 1 A27 60095013 Brine Piston Rod 1...

Page 30: ...47 B48 B49 B50 B1 B2 B3 B4 B5 B6 B7 B10 B11 B51 B52 B53 B3 B4 B39 B40 B41 B42 B43 B17 B17 B14 B16 B44 B29 B30 B31 B32 B34 B35 B36 B37 B32 B38 B16 B19 B20 B21B22B23B24B25 B16 B14 B33 B14 B14 B17 B45 B4...

Page 31: ...26 Meter Assembly B19 60010225 Magnet 4 3 B20 95 Meter B21 Meter PinTop Bush B22 Meter Pin Bush B23 Meter Ball B24 Meter Pin B25 Impeller Holder B27 60010214 Valve Connector NPT 1 25 B28 60010216 O ri...

Page 32: ...scription DLFC Options 60010144 2 9 5 gpm Flat 60010145 3 12 5 gpm Flat 60010146 4 16 5 gpm Flat 60010142 7S 7 0 gpm Flat Connector Options 60010213 Valve Connector NPT 1 60010215 Valve Connector NPT...

Page 33: ...ntrol DLFC button Check for proper ow rate 1 Plugged injector or screen Clean parts 2 Valve not regenerating Replace circuit board motor or control 3 Foreign material in brine valve Clean parts 4 Unit...

Page 34: ...ee from damage Flow control s cleaned and free from damage Piston clean and free from damage Confirm ball valve s fuction if applicable Brine float cleaned and free of damage Brine Tank cleaned Flow m...

Page 35: ...oor each tank Treated Water Hardness each tank Brine tank overflow connection s installed to drain and clean Total system treated water For warranty claims Canature WaterGroup reserves the right to as...

Page 36: ...2 Tank 3 Tank 4 Date Height of brine from ground Number of regenerations completed For warranty claims Canature WaterGroup reserves the right to ask for this maintenance sheet Failure to provide this...

Page 37: ...and brine Date Date Brine tank full of salt and brine Raw water hardness Treated hardness system Alarms Alarms For warranty claims Canature WaterGroup reserves the right to ask for this maintenance sh...

Page 38: ...ponding softener tank Weight of Salt added Date Number of regeneration s for corresponding softener tank Weight of Salt added For warranty claims Canature WaterGroup reserves the right to ask for this...

Page 39: ......

Page 40: ...the fiberglass tank has a tripod base it must have been properly and securely attached to the floor If not done or improperly installed the tank warranty will be void At our sole discretion we will re...

Reviews: