Subsection 03 (IGNITION SYSTEM)
Testing the Emergency Engine Stop
Switch at Multifunction Switch
Connectors
Refer to
WIRING HARNESS AND CONNECTORS
subsection for connector locations.
The emergency engine stop switch is wired into
the LH multifunction switch connectors (MG1 and
MG2).
1. Remove gauge support, refer to
LIGHTS,
GAUGE AND ACCESSORIES
subsection.
2. Disconnect MG1 and MG2 connectors.
3. Test switch continuity as per following table.
EMERGENCY ENGINE STOP SWITCH PIN-OUT
FUNCTION
PROBE
RESULT
MG1-3 to
MG2-3
Open circuit
RUN position
MG1-1 to
MG1-2
MG1-3 to
MG2-3
Close to 0
STOP position
MG1-1 to
MG1-2
Open circuit
If switch tests good, test continuity of wiring. Re-
fer to
WIRING DIAGRAM
.
IGNITION COIL
vmr2006-018-100
Ignition Coil Access
Refer to
BODY
subsection and remove RH inner
fender panel(s) for access to the ignition coil.
vmr2012-031-002_a
TYPICAL
1. Ignition coil location
Installing the Ignition Coil
Install a new elastic nut and tighten to the speci-
fied torque.
TIGHTENING TORQUE
Ignition coil retaining bolt
8 N•m ± 1 N•m
(71 lbf•
in
± 9 lbf•
in
)
Testing the Ignition Coil Input Voltage
1. Disconnect the 3-pin connector from the igni-
tion coil. Refer to
IGNITION COIL ACCESS
.
tmr2011-026-002_a
1. Ignition coil connector
2. Set emergency engine stop switch to RUN.
3. Turn ignition switch to ON.
4. Read voltage as per following table.
REQUIRED TOOL
FLUKE 115 MULTIMETER
(P/N 529 035 868)
vmr2016-134
3